Multi-Phase Charging Process - Pro-Logix PL2320 Operator's Manual

Battery charger
Table of Contents

Advertisement

Available languages

Available languages

CHARGING PROGRESS AND DISPLAY FEEDBACK

MULTI-PHASE CHARGING PROCESS

V
14
CONSTANT CURRENT
12
10
8
6
4
2
0
PHASE 1
STATUS
ENERGIZING
INDICATORS
ON
CHARGING
COMPLETE
OFF
The charger uses a proprietary Multi-Stage charging process designed to optimally charge and maintain batteries. An
example is shown above. The representation above shows the charging routine when charging a deeply discharged
AGM battery in the 20A setting. (The charging routine for Model PL2310 is similar, simply with lower charging rates.)
ENERGIZING PHASE
The charging process includes an initial energizing mode in which the charger determines the best charging path for
the connected battery. From there, the charger can enter the Fast Charge stage (most cases), Soft Start Mode, Battery
Recondition Mode or stop the charging routine because unsafe battery conditions (short, etc.) are detected.
SOFT START MODE
Soft Start Mode is activated when the charger is connected to a deeply discharged battery. This mode protects the battery
during the initial charge period, as the battery's voltage rises to a more normal level, and is beneficial for the long-term
health of the battery.
BATTERY RECONDITION MODE
During the Energizing Phase, if the charger detects the presence of battery sulfation, it will activate this mode. If this
occurs, the CHARGING LED will flash. This indicates the charge time will be extended while the charger attempts to
recondition the battery.
PRO-LOGIX PHASES 5-7: IDEAL BATTERY MAINTENANCE
A key feature of this charger is how it manages a battery that remains on the charger after a complete charge has been
achieved, such as during the storage of a seasonal use vehicle. Once the charger reaches the Resting Phase, its output
is virtually turned off, except to occasionally monitor battery condition. This is beneficial for the connected battery, as it
reduces chemical reaction within the battery compared to traditional charger maintenance modes. This greatly reduces the
chance of damaging a battery in long-term storage.
In addition, in Phase 6 Exercising, we introduce a load on the battery, simulating active use, and then recharge the battery
to full charge. This Exercising feature keeps the battery in optimal condition during periods of storage and non-use.
DISPLAY OPTIONS
Other than when the charger is in Exercising Phase or an Error is detected, the charger's display will offer two options
as to the information shown: Battery Voltage or Battery Percent of Charge. To change the display from one mode to the
other, press the Arrow button below the display.
CONSTANT
VOLTAGE
PHASE 2
PHASE 3
FAST CHARGE
ABSORPTION
ON
ON
OFF
OFF
PHASE 4
PHASE 5
COMPLETION
RESTING
FLASHING
OFF
ON
ON
VOLTAGE
CURRENT
DISPLAY = EP
PHASE 6
PHASE 7
EXERCISING
RESTORING
FLASHING
FLASHING
ON
ON
21
18
15
12
9
6
3
0
-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pl2310

Table of Contents