ELECTRICAL ADJUSTMENT-8/8
QQ
3 7 63 1515 0
3. Jitter Check
1) While oscilloscope is kept connected in the same test point as in
step2. RF WAVEFORM CHECK, connect the output terminal of
an oscillo scope to the input terminal of the jitter meter.
2) Set the VOLT range selector of oscilloscope to 500mV range or below.
3) Play back 2
nd
track of TCD-782.
4) Check that jitter meter indicates 28.0ns or less.
4. Traking Balance Check
1) Connect the TE and Vref to the oscilloscope.
2) Playback the second track of TCD-782 and press the PAUSE butten.
3) Check that the ttaverse waveforms of oscilloscope are up and down symmetrical.
5. Play Ability Check
1) Play back the 3
rd
, 8
th
and 13
TE
occur.
L 13942296513
www
.
http://www.xiaoyu163.com
th
track of ATD-001. Check that the noise does not occur sound skipping does not