Aiwa XR-EM30 Service Manual page 42

Hide thumbs Also See for XR-EM30:
Table of Contents

Advertisement

ELECTRICAL ADJUSTMENT-7/8
QQ
3 7 63 1515 0
CD CHECK
Perform the adjustments after the main unit enters the test mode.
Place the CD mechanism on level ground.
Equipment and tools required
Measuring equipment
Digital multi-meter
Jitter meter (KIKUSUI 6235)
Test disc: TCD-782
ATD-001
TE
L 13942296513
1. Focus Offset Adjustment
1) Connect a digital multimeter to the FE and Vref.
2) Playback the second track of the TCD-782.
3) Adjust SFR501 until the digital multimeter indicates 20
2. Rf Waveform Check
1) Connect oscilloscope to the test point RF and Vref.
2) Play back the 2
nd
track of TCD-782.
3) Check that the RF waveform has the maximum amplitude and the center
of the wedge waveform has the clear blank.