Mitsubishi Electric MXZ-3C54VA Service Manual page 14

Outdoor unit
Hide thumbs Also See for MXZ-3C54VA:
Table of Contents

Advertisement

MXZ-4C80VA MXZ-5C100VA
200
35
250
Air in
3- 33 Drain hole
Handle
317
1.Installation space
Note : Leave front and both sides
free of obstruction.
Note : Leave front and overhead
free of obstruction.
Note : Leave rear, overhead and
both sides free of obstruction.
500
200
2-U Shaped notched hole
270
(Base bolt M10)
Air in
Air out
2-12 x 36 Oval hole
(Base bolt M10)
900
Handle
23
100 or more
30
Indoor and
outdoor
connect
wiring
(35 x 53) hole
Liquid pipe
6.35(flared)1/4
100 or more
350 or more
14
Gas pipe
9.52(flared) 3/8 (B,C,D,E (MXZ-5C100VA) unit)
12.7(flared) 1/2 (A unit)
320
10
88
E unit connection (MXZ-5C100VA)
D unit connection
C unit connection
B unit connection
B
A unit connection
A
2.Service space
100 or more
350 or more
Unit: mm
350 or more
Service space