5.7
3-way diverter valve
B Power OFF the appliance.
B Disconnect the boiler electrical connection.
B Turn off service cocks.
B Drain appliance.
B Unplug connector from 3-way valve motor.
B Pull out retaining clip.
B Remove motor.
B Open pipe joints.
B Remove 3-way valve.
Fig. 14
After refitting:
B Fill system, bleed and re-pressurise (see Installation
Instructions).
7 181 465 347 (05.01)
Supplied By www.heating spares.co Tel. 0161 620 6677
5.8
Domestic Hot Water Heat
Exchanger
B Power OFF the appliance.
B Turn off service cocks.
B Drain appliance.
B Open pipe joints.
Fig. 15
B Remove the domestic hot water heat exchanger.
After refitting:
B Fill system, bleed and re-pressurise (see Installation
Instructions).
5.9
Electrode assembly
B Power OFF the appliance.
B Disconnect the boiler electrical connection.
B Unscrew the two fixing screws and carefully remove
the electrode assembly. Refer to fig. 1).
B Remove electrode assembly and bracket and check
for wear, deposits and mechanical damage.
B Replace assembly if necessary.
Replacement of Parts