Way Diverter Valve - Worcester ZWBR 7-30 R 30 HE PLUS COMBI Service Booklet

Gas condensing boiler
Hide thumbs Also See for ZWBR 7-30 R 30 HE PLUS COMBI:
Table of Contents

Advertisement

5.7

3-way diverter valve

B Power OFF the appliance.
B Disconnect the boiler electrical connection.
B Turn off service cocks.
B Drain appliance.
B Unplug connector from 3-way valve motor.
B Pull out retaining clip.
B Remove motor.
B Open pipe joints.
B Remove 3-way valve.
Fig. 14
After refitting:
B Fill system, bleed and re-pressurise (see Installation
Instructions).
7 181 465 347 (05.01)
Supplied By www.heating spares.co Tel. 0161 620 6677
5.8
Domestic Hot Water Heat
Exchanger
B Power OFF the appliance.
B Turn off service cocks.
B Drain appliance.
B Open pipe joints.
Fig. 15
B Remove the domestic hot water heat exchanger.
After refitting:
B Fill system, bleed and re-pressurise (see Installation
Instructions).
5.9
Electrode assembly
B Power OFF the appliance.
B Disconnect the boiler electrical connection.
B Unscrew the two fixing screws and carefully remove
the electrode assembly. Refer to fig. 1).
B Remove electrode assembly and bracket and check
for wear, deposits and mechanical damage.
B Replace assembly if necessary.