Worcester ZWBR 7-30 R 30 HE PLUS COMBI Service Booklet page 13

Gas condensing boiler
Hide thumbs Also See for ZWBR 7-30 R 30 HE PLUS COMBI:
Table of Contents

Advertisement

The factory setting is:
7.0 Pump map (heating) 3 Const. pressure low
0,6
H
(bar)
0,5
1
2
0,4
0,3
0,2
0,1
0
0
200
400
600
Fig. 3
Constant pressure
1-5
Caracteristics
H
Pressure
Q
Water circulation rate
0,6
H
(bar)
0,5
4
5
0,4
0,3
0,2
0,1
0
0
200
400
600
Fig. 4
Proportional pressure
If this parameter is set to Pump step adjustable then
the pump speed set under function 7.1 Map pump
step (heat.) is active.
7 181 465 347 (05.01)
Supplied By www.heating spares.co Tel. 0161 620 6677
3
800
1000
1200
1400
1600
Q
(l/h)
6 720 610 587-43.1O
800
1000
1200
1400
1600
Q
(l/h)
6 720 610 587-44.1O
7.1 Map pump step (heat.)
This service function corresponds to the pump speed
switch used on conventional heating pumps.
However, the setting is only active if function 7.0 Pump
map (heating), is set to Pump step adjustable.
The factory setting is:
7.1 Map pump step (heat.) 7
0,6
H
(bar)
0,5
0,4
0,3
0,2
4
3
2
0,1
0
0
200
400
600
Fig. 5
Caracteristics
2-7
Caracteristics
H
Pressure
Q
Water circulation rate
7.2 Antiblock. map pump
The appliance is supplied with this function activated.
If the pump threatens to jam, an oscillating pump action
is activated. Afterwards, the required operating mode is
continued.
Boiler service functions
7
6
5
800
1000
1400
1600
1200
Q
(l/h)
6 720 610 587-45.1O
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents