Controls And Indicators; Operation Instructions - Central Pneumatic 95370 Assembly And Operation Instructions Manual

Table of Contents

Advertisement

2.
Connect the high pressure air hose to the Air Outlet (A27). Refer to Controls and
Indicators below. The outlet is 1/4" x 18 NPT. For easy connection or removal, a
quick coupler (not supplied) should be installed on the the air outlet.
3.
To extend the life of most air tools, it is recommended to install an oiler and water
filter in series with the air output line of the Air Compressor as shown below.
4.
Connect the other end of the high pressure air hose to the air tool.
wARNING! : do not remove or try to adjust the factory sealed Pressure Switch
(A29); removal can cause the Tank to over pressurize and explode.
Purchase a 3-prong, twist-lock, 220 VAC line plug for the Air Compressor line cord.
Have a qualified electrician connect the plug the line cord.
Auto-ON
Pressure Switch
for technical questions, please call 1-800-444-3353.
SKU 95370
Typical Air Compressor/Air Tool Set up
Connect 220 V Line Plug

OPERATION INSTRuCTIONS

Controls and Indicators

OFF
Tank Air
Pressure Gauge
Adjustment
Output Air
Pressure Gauge
Pressure
Air Outlet
Page 9