ELECTRICAL
It is necessary to provide
an appropriate
junction
box as shown on the previous
page. The installation
ot
this junction
box and the wiring
connecting
it to the hollse wiring
should be done by a qualified
electrician.
All wiring
must be done in accordance
with
the Natioral
Electrical
Code and/or any other applicable
local
codes or ordinances.
The power supply
to the junction
box must be 120/240
volt or 120/208 volt,
60
hertz A.C. single phase, 3
wire.
Do not connect
the oven to a D.C. power suppllr as serious damage to the components
will
result.
Refer to TABLE
1 for fuse or circuit
breaker size for
the
model being installed.
Remember
that the oven
must have a separate circuit.
Do not operate other electr cal equipment
on the same cirucit.
TABLE
1
Model No.
KESO-140/170
KESO-145/176
SCO- 1243/l
273
SCO-243312733
Maximum
Wattage
3.8KW@;40V
Fuse or Breaker
Size Required
30 AMPS
KEDO-2401270
SCO-224312273
KEDO-245/276
SCO-244312743
6.0
KW@ 240 V
7.5
KW @ 240 V
40 AMPS
UNPACKING
THE UNIT
The oven should
be left on the carton
base until
it is ready to
put into the cabinet.
It is also recommended
that the patls over
the door(s)
be left in place. These precautions
will
reduce the
possibility
of damage to the front of the unit and the bot om of
the front
frame.
Prior to installation,
test the electrical
service to assure that it
agrees with the specifications
on the oven data plate.
Remove
all cords, tape and wire used to hold various
p3rts in
position
during shipment.
Remove oven racks from the inide
of
the oven and put to one side while
oven is being insta led in
cabinet.
Take broiler
pan and grid from packing
on top If the
oven and keep with
literature
packet in a location
when: they
will be retained
by the owner.
To Remove Oven Rack8
Slide
rack forward until
bar on back of rack
touches
first stop.
Lift front
of rack until rear portion
of rack
slides out between
front two stops.
ELECTRICAL
CONNECTION
WARNING:
ELECTRICAL
AND
GROUNDING
CONhECTlONS
MUST
COMPLY
WITH
THE APPLI-
CABLE
PORTIONS
OF THE NATIONAL
ELECTRICAL
CODE AND/OR
OTHER
LOCAL
ELECTRICAL
CODES.
WARNING:
DISCONNECT
ELECTRICAL
POWER SU'PLY
AND
PLACE
A TAG AT THE
DISCON-
NECT SWITCH
INDICATING
THAT
YOU ARE WORKING
ON THE CIRCUIT.
Connect
the conduit
from the oven to the junction
box
jnd properly
connect
to the power supply
leads.
Bare to ground,
black to L2, red to Ll, white to neutral or according
to local code.)
GROUNDING
-THE
OVEN MUST BE GROUNDED.
Do not work on the oven wiring
until the oven has been pc sitively
grounded.
The oven frame is grounded
through
the bare groundiny
wi-e. Connect
it to ground
in accordance
with
local
codes. Connect
the white
neutral to the service neutral win at the junction
box.