Make sure the USB communications hub is not
obstructed and is easily accessible to the computer.
To completely disconnect from power, the USB
should be disconnected from the PC.
This product should be supplied by an identical USB
port complying with the requirements of Limited
Power Source.

MoUNtING / PLACING oF SENSoRS

REMotE WINd SENSoR oN EXIStING PoLE

1
. Secure the plastic base onto existing pole with U-
bolts, washers and bolts.
2. Insert the horizontal attachment bracket into the base.
3. Using a screw, fix firmly into place.
16 4
5
4. Insert wind sensor into the top of the bracket.
5. Using screws, fix aluminium pole firmly into place.
6. Slide outdoor sensor onto bracket.
IMPoRtANt For best results, point the wind vane North.
9
7
8
7. Slide the solar panel connector into place on the other
side of the bracket. Slot the solar panel in place.
8. Adjust the solar panel. Once facing desired direction,
use screw to fix in place.
9. Loosen the wing bolt and adjust the angle. Tighten
wing bolt to secure solar panel at desired angle.
0. Remove outdoor sensor from casing. Plug one solar
panel cable into the socket. Replace sensor into the
casing.
NotE For best results, direct solar panel as follows:
Solar panel facing:
North
South
WMR180_UM_EN_R7.indd 6
3
2
6
10
If you reside in the:
Southern Hemisphere
Northern Hemisphere
. Plug the other solar panel cables into the socket on
the wind vane.
NotE There are slots to insert the solar power cable
for convenient storage. There are also fasteners to help
tighten the cables.
tEMPERAtURE / HUMIdItY SENSoR
MoUNtEd SEPARAtELY
. Insert 4 type A screws into the holes of the sensor
connector. Screw firmly into place, i.e., fence.

RAIN GAUGE

The base station and rain gauge should be positioned
within an effective range: about 00 meters (328 feet)
in an open area.
The rain gauge should be mounted horizontally about 
meter (3 feet) from the ground in an open area away from
trees or other obstructions to allow rain to fall naturally
for an accurate reading.
to ensure a level plane:
Put a few drops of water on the cross at the base of the
funnel to check the horizontal level.
Water will pool to the center of the cross when the rain
gauge is level.
6