Thermostat Adjustment; Temperature-Pressure Relief Valve Operation - Maytag SERIES NINE HE2940L User Manual

Series nine
Table of Contents

Advertisement

Service and Maintenance
(cont'd)
Thermostat Adjustments
Temperature-Pressure
Relief
Valve Operation
If the upper thermostat is adjusted above the factory preset
point of 120°F (Hot), it cannot be set higher than the lower
The temperature-pressure
relief valve must be manually oper-
thermostat setting. Read all warnings in the "Temperature
ated at least once a year.
Regulation" section before proceeding.
UPPER THERMOSTAT
/
TEMPERATURE-PRESSURE
/
RELIEF V ALVE
1. Turn "off" the electtic power to the water heater at the
_31_
__
junction box.
AWARNING
HAZARD OF ELECTRICAL SHOCK! Before removing
any access panels or servicing the water
heater,
make sure the electrical supply to the water heater
DISCHARGE PIPE
is turned "OFF". Failure to do this could result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE.
_,WARNING
The temperature-pressure
relief
valve
must
be
2. Take offthe access panel,
manually
operatedat
least once a year. Caution
should be taken to ensure that (1) no one is in front
3. The slotted adjustment (using a screwdriver) can be turned
of or around the outlet of the temperature-pres-
clockwise (t'-_
to increase the temperature
setting or
sure relief valve discharge line, and (2) the water
manually
discharged will not cause any property
counterclockwise
(¢"-_
to decrease the temperature
damage
or bodily
injury.
The water
may be
setting,
extremely hot.
If after
manually
operating
the valve, it fails to
completely
reset and continues
to release water,
4. Replace the access panel,
immediately
close the cold water inlet to the water
heater,
follow
the draining
instructions,
and
5. Turn "ON" the power supply,
rep ace the temperature-pressure
re ief valve witf
a new one.
Failure to install and maintain a new properly listed tempera-
LOWER
THERMOSTAT
ture-pressure relief valve will release the manufacturer from
The adjustment dial can be turned clockwise (_--'_)
to
any claim which might result from excessive temperature or
increase the temperature
setting or counter clockwise
pressure.
(_-'_)
to decrease the temperature setting.
_WARNING
If the temperature-pressure
relief
valve on the
appliance
weeps
or discharges
periodically,
this
may be due to thermal
expans on. Your water
I heater
may have a check valve installed
in the
water line or a water meter with a check valve. Call
Maytag Customer Service at 1-800-788-8899
for an
authorized
servicer. Do not plug the temperature-
pressure relief valve.