Troubleshooting Guidelines - Maytag HVN41240PCGA User Manual

Series twelve power vent gas water heater
Table of Contents

Advertisement

TROUBLESHOOTING GUIDELINES

TROUBLESHOOTING GUIDELINES
These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag Customer Service Center at
1-800-788-8899 for assistance. Inform the associate that this is a "Flammable Vapor Ignition Resistant" Product.
LED STATUS
An open earth ground circuit to the
A B C
ignition system.
Wiring error or a high resistance to
A B C
earth ground.
Pressure switch remained closed longer
A B C
than 5 seconds after the call for
heat began.
Pressure switch remained open longer
A B C
than 5 seconds after the combustion
blower was energized.
A B C
Error in the hot surface ignitor circuit.
System in lockout.
A B C
A B C
Problem in the gas valve driver circuit.
Problem with the internal circuit.
A B C
A B C
Problem with the internal circuit.
A B C
Flame signal sensed out of
proper sequence.
A B C
ECO activated.
A B C
One of the temperature adjust
buttons stuck closed.
A B C
Water temperature sensor is
either open or short circuited.
A B C
Unit shuts down and in lockout.
A B C
Unit shuts down.
A B C
Unit shuts down and in lockout.
PROBLEM
29
SOLUTION
1. Check that the earth ground connection is
properly connected.
2. Check that the ground conductor on the
water heater is properly connected.
1. Check for proper connection of line
neutral and hot wires.
2. Check that the water heater is securely
connected to earth ground.
1. Pressure switch wiring is incorrect.
2. Replace pressure switch.
1. Pressure switch wiring is incorrect.
2. Pressure switch tubing not connected
correctly.
3. Air intake or exhaust obstructed.
1. Check that all wiring is correct and secure.
2. Replace hot surface ignitor.
1. Gas supply is off or too low to operate.
2. Hot surface ignitor not positioned
correctly.
3. Low voltage to the water heater.
4. Electric polarity to unit is incorrect - test
and correct.
1. Turn power to the water heater off for
10 seconds and the back on.
2. Replace gas control valve.
1. Turn power to the water heater off for
10 seconds and then back on.
2. Replace gas control valve.
1. Turn power to the water heater off for
10 seconds and then back on.
2. Replace gas control valve.
1. Replace gas control valve.
1. Replace gas control valve.
1. Press and release each of the buttons
once.
2. Replace gas control valve.
1. Check that all wiring is correct and secure.
2. Replace gas control valve.
1. Clean and reinstall the air intake screen.
2. Clean and reinstall the lint screen on the
Blower assembly.
1. Check for correct wiring to FV sensor.
2. Check for open circuits to FV sensor.
3. Replace FV sensor.
1. FV sensor detected presence of flammable vapors.
2. Contact Maytag Customer Service (1-800-788-8899)
to determine cause.