READ THEINSTALLA770N INSR?UCRONS CAREFUUYAND
COMPLETELYBEFORE YOU BEGIN.
IMPORZANTN07ES:
Follow National Electiic Codes (NEC) andjor local codes and ordinances.
For personal safe~ this system must be properly grounded.
Protective devices (fuses or circuit breakers) acceptable for installation are specified on the
nameplate of each unit
Servicing and installation of the refrigerant system must be petiormed only by a licensed, tiVAC
cetified technician.
Make sure to avoid wiring or plumbing inside the wall when installing.
II
1
hr any sem-ce which requin?sentry into the refrigerant sealed system, hderal regulations mquim tie
work be performed by a technician having a Class II or Univemal certification.
. \\ I //
CAUTION
Electrical Requirements
Be certain all wiring complies with local building codes and NEC and that the supply voltage for this
system is correct The system supply voftage is connected to the outdoor unit only
Check the rating nameplate on side panel of outdoor unit for required circuit protection rating and
required supply voltage.
Use Underwriters-approved
electrical branch circuit disconnect for providing supply voltage to split
system outdoor unit Locate disconnect within sight and readily accessible from outdoor unit.
The sphl system indoor unit requires low voftage (D.C.) supplied from the outdoor unit via
interconnecting
wiring. The interconnecting wiring between indoor and outdoor units of this
system must be 18-4 wiring, 18-gauge (minimum), 300-volt rating, type SJO–WA or STO–WA.
Be ceflain there is an uninterrupted, unbroken electrical ground connection.
Electric drill
'z Pencil
Carpenter$ stud finder (recommended)
" Crescent wrench
;,
2 Y–3" diameter hole saw
N07E:
A licensed, certified (to hand/e refrigerant-22,
Phillips-head screwdriver
recovety etc.) technician is required for installation of
these split air conditioning or heating pump systems.