Sign In
Upload
Manuals
Brands
Daikin Manuals
Air Conditioner
RX60G4V1B
Daikin RX60G4V1B Manuals
Manuals and User Guides for Daikin RX60G4V1B. We have
3
Daikin RX60G4V1B manuals available for free PDF download: Service Manual, Installation Manual
Daikin RX60G4V1B Service Manual (130 pages)
Brand:
Daikin
| Category:
Heat Pump
| Size: 3.61 MB
Table of Contents
Table of Contents
3
Safety Cautions
6
Warnings and Cautions Regarding Safety of Workers
6
Warnings and Cautions Regarding Safety of Users
8
Used Icons
11
Part 1 List of Functions
12
Functions
13
Part 2 Specifications
14
Specifications
15
Part 3 Printed Circuit Board Connector Wiring Diagram
22
Indoor Unit
23
Outdoor Unit
25
RX50/60G2V1B, 71 Class
25
Rx50/60G2V1B9, Rx50/60G3V1B, Rx60G4V1B
27
Part 4 Function and Control
29
Main Functions
30
Temperature Control
30
Frequency Principle
30
Airflow Direction Control
32
Fan Speed Control for Indoor Unit
33
Program Dry Operation
34
Automatic Operation
35
Thermostat Control
36
NIGHT SET Mode
37
HOME LEAVE Operation
37
INTELLIGENT EYE Operation
39
Inverter POWERFUL Operation
40
Clock Setting
40
Other Functions
41
Function of Thermistor
42
Control Specification
43
Mode Hierarchy
43
Frequency Control
44
Controls at Mode Changing / Start-Up
46
Discharge Pipe Temperature Control
48
Input Current Control
49
Freeze-Up Protection Control
50
Heating Peak-Cut Control
50
Outdoor Fan Control
51
Liquid Compression Protection Function
51
Defrost Control
52
Electronic Expansion Valve Control
53
Pressure Equalizing Control
54
Malfunctions
56
Part 5 Remote Controller
57
Remote Controller
58
Mode Button
59
Part 6 Service Diagnosis
60
General Problem Symptoms and Check Items
62
Troubleshooting with LED
63
Indoor Unit
63
Outdoor Unit
63
Service Diagnosis
64
Troubleshooting
67
Error Codes and Description
67
Indoor Unit PCB Abnormality
68
Freeze-Up Protection Control / Heating Peak-Cut Control
69
Fan Motor (DC Motor) or Related Abnormality
70
Thermistor or Related Abnormality (Indoor Unit)
72
Refrigerant Shortage
73
Low-Voltage Detection or Over-Voltage Detection
75
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
77
Signal Transmission Error on Outdoor Unit PCB (RX50/60G2V1B, 71 Class Only)
79
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
80
Outdoor Unit PCB Abnormality
81
OL Activation (Compressor Overload)
83
Compressor Lock
85
DC Fan Lock
86
Input Overcurrent Detection
87
Four Way Valve Abnormality
88
Discharge Pipe Temperature Control
90
High Pressure Control in Cooling
91
Compressor System Sensor Abnormality
92
Position Sensor Abnormality
94
CT or Related Abnormality (RX50/60G2V1B, 71 Class Only)
97
Thermistor or Related Abnormality (Outdoor Unit)
99
Electrical Box Temperature Rise
101
Radiation Fin Temperature Rise
102
Output Overcurrent Detection
104
Check
106
Thermistor Resistance Check
106
Indoor Fan Motor Connector Output Check
107
Power Supply Waveforms Check
107
Electronic Expansion Valve Check
107
Four Way Valve Performance Check
108
Inverter Unit Refrigerant System Check
108
Inverter Analyzer Check
109
Rotation Pulse Check on the Outdoor Unit PCB
110
Installation Condition Check
111
Discharge Pressure Check
111
Outdoor Fan System Check
112
Main Circuit Short Check
112
Capacitor Voltage Check
113
Power Module Check
113
Part 7 Trial Operation and Field Settings
115
Pump down Operation
116
Forced Cooling Operation
117
Trial Operation
118
Field Settings
119
When 2 Units Are Installed in 1 Room
119
Facility Setting (Cooling at Low Outdoor Temperature)
120
Jumper and Switch Settings
121
Silicon Grease on Power Transistor / Diode Bridge
122
Part 8 Appendix
123
Piping Diagrams
124
Indoor Unit
124
Outdoor Unit
124
Wiring Diagrams
126
Indoor Unit
126
Outdoor Unit
127
Revision History
129
Advertisement
Daikin RX60G4V1B Installation Manual (20 pages)
R410A split series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 3.24 MB
Table of Contents
Installation Manual
1
1 About this Document
6
Table of Contents
6
Meaning of Warnings and Symbols
6
2 General Safety Precautions
7
3 About the Box
8
Outdoor Unit
8
To Remove the Accessories from the Outdoor Unit
8
4 Preparation
8
Preparing Installation Site
8
Installation Site Requirements of the Outdoor Unit
8
Additional Installation Site Requirements of the Outdoor Unit in Cold Climates
9
Preparing Refrigerant Piping
9
Refrigerant Piping Requirements
9
Refrigerant Piping Insulation
9
5 Installation
10
Opening the Units
10
To Open the Outdoor Unit
10
Mounting the Outdoor Unit
10
To Provide the Installation Structure
10
To Install the Outdoor Unit
11
To Provide Drainage
11
To Prevent the Outdoor Unit from Falling over
11
Connecting the Refrigerant Piping
12
Precautions When Connecting the Refrigerant Piping
12
Guidelines When Connecting the Refrigerant Piping
12
Pipe Bending Guidelines
12
To Flare the Pipe End
12
Using the Stop Valve and Service Port
13
To Connect the Refrigerant Piping to the Outdoor Unit
13
Checking the Refrigerant Piping
14
To Check for Leaks
14
To Perform Vacuum Drying
14
Charging Refrigerant
14
To Determine the Additional Refrigerant Amount
14
To Charge Refrigerant
14
To Fix the Fluorinated Greenhouse Gases Label
15
Connecting the Electrical Wiring
15
Specifications of Standard Wiring Components
16
To Connect the Electrical Wiring on the Outdoor Unit
16
Saving Electricity Using the Standby Mode
16
Cooling Equipment and Computer Rooms at Low Outdoor Temperatures
17
Finishing the Outdoor Unit Installation
17
To Finish the Outdoor Unit Installation
17
6 Commissioning
17
Precautions When Commissioning
17
Checklist before Commissioning
17
To Perform a Test Run
18
To Start and Stop Forced Cooling
18
Starting up the Outdoor Unit
18
7 Disposal
18
To Pump down
18
8 Technical Data
19
Wiring Diagram
19
Daikin RX60G4V1B Installation Manual (21 pages)
R410A Split Series
Brand:
Daikin
| Category:
Air Conditioner
| Size: 4.32 MB
Table of Contents
Installation Manual
1
Safety Precautions
5
Precautions for Selecting the Location
6
Outdoor Unit Installation Drawings
7
Precautions on Installation
8
Outdoor Unit Installation
8
Installing Outdoor Unit
8
Refrigerant Piping
9
Purging Air and Checking Gas Leakage
10
Refrigerant Piping Work
11
Pump down Operation
12
Standby Electricity Saving
12
Facility Setting (Cooling at Low Outdoor Temperature)
13
Wiring Diagram
15
Trial Operation and Testing
16
Advertisement
Advertisement
Related Products
Daikin RX60G3V1B
Daikin RX60CGXV1
Daikin RX60K(2)V1B
Daikin RX60KV1B
Daikin RX60AZVMB
Daikin RXYQ216PYDN
Daikin RX18NMVJU
Daikin RXS25DVMB
Daikin RXK35AV1B
Daikin RXYTQ14T7YF
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL