5 Installation
▪ Use the following methods for installing wires:
Wire type
Single core wire
A
a Curled single core wire
b Screw
c Flat washer
c b
Stranded conductor
wire with round
crimp-style terminal
a Terminal
b Screw
c Flat washer
Tightening torques
Item
M4 (X1M)
M4 (earth)
Equipment
complying
with
International Technical Standard setting the limits for harmonic
currents produced by equipment connected to public low-voltage
systems with input current >16 A and ≤75 A per phase.).
5.6.1
Specifications of standard wiring
components
Component
Power supply cable Voltage
Phase
Frequency
Wire sizes
Interconnection cable
Recommended field fuse
Earth leakage circuit breaker
5.6.2
To connect the electrical wiring on the
outdoor unit
1 Remove the outside panel.
2 Remove the switch box cover.
Installation manual
16
Installation method
c b
AA´
c
a
a
a
b
c
B
B
a
Tightening torque (N•m)
1.2~1.5
EN/IEC  61000‑3‑12
(European/
220~240 V
1~
50 Hz
Must comply with
applicable legislation
Minimum cable section of
2.5 mm² and applicable
for 220~240 V
20 A
Must comply with
applicable legislation
3 Open the wire clamp.
4 Connect the interconnection cable and power supply as follows:
1 2 3
5 Tighten the terminal screws securely. We recommend to use a
Philips screwdriver.
6 Install the switch box cover.
7 Install the outside panel.
5.6.3

Saving electricity using the standby mode

About the standby mode
This mode turns OFF the power supply of the outdoor unit and sets
the indoor unit into standby mode. It reduce the power consumption
of the indoor unit. This mode is only applicable for following models:
FTXS50K2V1B,
FVXG50K2V1B,
FTXG50LV1BS.
INFORMATION
The standby mode can ONLY used by the units as
described above.
WARNING
Before connecting or disconnecting the connector, make
sure the power is turned OFF.
INFORMATION
You MUST connect the connector if you use an indoor unit
where the standby mode is NOT applicable.
To set the standby mode
1 Turn OFF the power supply.
2 Remove the outside panel.
3 Remove the switch box cover.
4 Disconnect the connector for standby mode.
2
1
FTXG50LV1BW,
and
RXS50+60 + RX50+60 + ARXS50~71
R410A split series
3P360062-1H – 2016.09