S8 series ii positive airway pressure devices
Hide thumbs Also See for S8 AutoSet II:

Advertisement

S8 Series II
S8 AutoSet™ II
S8 Elite™ II
POSITIVE AIRWAY PRESSURE DEVICES
User Guide
Rx Only
English
©2008 ResMed Ltd.
338523-Eng/1 08 01

Advertisement

Table of Contents
loading

Summary of Contents for ResMed S8 AutoSet II

  • Page 1 S8 Series II S8 AutoSet™ II S8 Elite™ II POSITIVE AIRWAY PRESSURE DEVICES User Guide Rx Only English ©2008 ResMed Ltd. 338523-Eng/1 08 01...
  • Page 2: Table Of Contents

    ........1 Indications for Use S8 AutoSet II S8 Elite II .
  • Page 3: Indications For Use

    Indications for Use S8 AutoSet II The S8 AutoSet II self-adjusting sleep apnea system is indicated for the treatment of obstructive sleep apnea (OSA) in adult patients. The S8 AutoSet II self-adjusting sleep apnea system has two treatment modes: AutoSet and fixed-pressure CPAP.
  • Page 4: Masks

    Make sure the power cord and plug are in good condition and the • equipment is not damaged. Only ResMed air tubing should be used with the device. A different type of • air tubing may alter the pressure you actually receive and reduce the effectiveness of your treatment.
  • Page 5: Connecting The Device

    With the RAMP or SETTLING screen displayed, press . (In CPAP mode, the standby screen displays RAMP. In AutoSet mode (S8 AutoSet II only) the standby screen displays SETTLING.) Press until MASK is displayed.
  • Page 6: Starting Treatment

    Your device will ramp to the mask-fit pressure and will remain at this pressure for three minutes. The following displays on the LCD screen indicating that the mask-fitting feature is operating, where: ***** is an excellent fit;****- is a very good fit; ***-- is a good fit;...
  • Page 7: Stopping Treatment

    * Only displayed if access set by clinician. Note: The AutoSet menu is available on the S8 AutoSet II only. To enter the standard menu from the standby (RAMP or SETTLING) screen, press Changing the Settings on your S8 II Device...
  • Page 8 You can use this menu to change the: Expiratory Pressure Relief (EPR) settings • Your clinician may have set up your device to deliver EPR. This can be used to help ease any discomfort you may experience when breathing out during treatment. There are four settings: OFF (no EPR);...
  • Page 9: The Detailed Menu

    * Only displayed if access set by clinician. Note: The AutoSet menu is available on the S8 AutoSet II only. To enter the detailed menu from the standby (RAMP or SETTLING) screen, press The SETTINGS menu screen is displayed.
  • Page 10 Results menu to access the options in this menu. You can use the Results menu to view the total number of hours of treatment (USED HRS) and the number of sessions that the S8 AutoSet II was used in a usage period (USAGE).
  • Page 11: Messages On The S8 Series Ii Lcd

    Messages on the S8 Series II LCD Your clinician may have set your S8 Series II device to remind you about important events, such as when to replace your mask, when to insert your Data Card (if your device is Data Card enabled) and so on. The reminder message is displayed on the LCD and is visible if the device is not delivering therapy.
  • Page 12: Cleaning And Maintenance

    Remove the Data Card by gripping the end of the Data Card and pulling it out. Store the Data Card in its protective folder when not in use. Return the card in its protective folder to your clinician using a postal envelope. Using the Data Card to Update Settings If your clinician has provided a Data Card with new device settings: With the device in standby (Ramp) mode, insert the Data Card into the Data Card...
  • Page 13: Monthly

    Replace the air filter cover Servicing This product (S8 AutoSet II; S8 Elite II) should be inspected by an authorized ResMed service centre five years from the date of manufacture. Prior to this, the device is intended to provide safe and reliable operation provided that it is operated and maintained in accordance with the instructions provided by ResMed.
  • Page 14: Frequently Asked Questions

    Frequently Asked Questions How will it feel when I am breathing with the S8 Series II? When you first use your S8 Series II, you may feel uncomfortable breathing against the airflow. This is normal. You will continue to breathe normally while you sleep. The EPR setting may also improve comfort.
  • Page 15: Troubleshooting

    Troubleshooting If there is a problem, try the following suggestions. If the problem cannot be solved, contact your equipment supplier or ResMed. Do not attempt to open the device. Problem/Possible Cause Solution No display Power is not connected. Ensure the power cable is connected and the power switch (if available) is on.
  • Page 16 Problem/Possible Cause Solution Displays error message: or Exxxx (where SYSTEM ERRxxxx Call Service! xxxx defines an error) Component failure. Record error number and call service. Displays error message: Check tube!! Key if done Air tubing is loose or blocked. Check that the air tubing is connected securely to your mask and the air outlet to the front of the S8 Series II.
  • Page 17: Technical Specifications

    (EMC) according to IEC60601-1-2, for residential, commercial and light industry environments. The electromagnetic compatibility tables for these ResMed devices can be found on www.resmed.com, on the Products page under Service and Support. Click on the PDF file for your device.
  • Page 18 A patient should not connect a device to the data communication port unless • instructed to do so by their health care provider or physician. Only ResMed products are designed to be connected to the data communication port. Connecting other devices could result in injury, or damage to the S8 Series II device.
  • Page 19 Caution should be exercised if the room temperature is warmer than 90ºF (32ºC). When using DC power, always use a ResMed DC-12 converter. (The DC-12 • converter is available as an optional accessory. It is not supplied with all models.) The device should not be connected to both AC and DC power sources simultaneously.
  • Page 20: Limited Warranty

    ResMed shall not be responsible for any incidental or consequential damages claimed to have occurred as a result of the sale, installation or use of any ResMed product. Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.