S8 Elite™ II System
User Guide

Advertisement

Table of Contents
loading

Summary of Contents for ResMed S8 Elite II

  • Page 1 S8 Elite™ II System User Guide...
  • Page 2 ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia • ResMed Corp (US Designated Agent) 14040 Danielson Street Poway CA 92064-6857 USA • ResMed (UK) Ltd (EU Authorised Representative) 65 Milton Park Abingdon Oxfordshire OX14 4RX UK • ResMed Offices Australia, Austria, Brazil, China, Finland, France, Germany, Hong Kong, India, Japan, Malaysia, Netherlands, New Zealand, Norway, Singapore, Spain, Sweden, Switzerland, UK, USA (see www.resmed.com for contact details).
  • Page 3: Table Of Contents

    INTEGRATED HUMIDIFIER SETTING UP THE S8 ™ S8 Elite II System Component of 338425/1 ILLUSTRATIONS SYSTEM COMPONENTS HumidAire 3i ™ Carry handle Keypad OTHER ACCESSORIES LCD screen Air outlet Air filter cover Module Air inlet DC input AC input Note: Some products not available in all regions.
  • Page 4 HUMIDAIRE 3i AND S8 USING THE DATA CARD HumidAire 3i BLANK MODULE D D a a t t a a c c o o m m m m u u n n i i c c a a t t i i o o n n s s p p o o r r t t DATA CARD MODULE Note: Some products not available in all regions.
  • Page 5 ........7 How to Use the S8 Elite II...
  • Page 6 ........31 System Specifications S8 Elite II (no Accessories) Accessories All Devices (where applicable) .
  • Page 7: Introduction

    Introduction Thank you for choosing the S8 Elite™ II flow generator. The S8 Elite II is a compact, all-in-one package with an inbuilt power supply and the option of integrated data management and humidification. This user manual contains the information you need for the correct use of your S8 Elite II.
  • Page 8: Medical Information

    The S8 Elite II CPAP system is intended for home and hospital use. Contraindications The S8 Elite II is not a life support device and may stop operating during power failure or certain fault conditions. It should not be used by patients who are dependent on continuous therapy.
  • Page 9: Cautions

    This applies to most models of CPAP devices. In the event of power failure or machine malfunction, remove the mask. • The S8 Elite II can be set to deliver pressures up to 20 cm H O. In the •...
  • Page 10: Adverse Effects

    Note: The above are general warnings and cautions. Specific warnings, cautions and notes appear with the relevant instructions in the manual. Adverse Effects Patients should report unusual chest pain, severe headache or increased breathlessness to their prescribing physician. An acute upper respiratory tract infection may require temporary discontinuation of treatment.
  • Page 11: S8 Elite Ii

    The S8 Elite II System The S8 Elite II device is part of a system that consists of five elements: S8 Elite II flow generator • Mask • Humidifier • Data management products • Accessories. • S8 Elite II Please refer to the illustrations in section A of the illustration sheet.
  • Page 12: Humidifier

    The ResScan™ Data Card module and ResScan Data Card (C-1) may be used with the S8 Elite II either to help your clinician to monitor your treatment or to provide you with updates to your device settings. See “Using a ResScan Data Card Module”...
  • Page 13: Assemble The Mask

    Note: You can also place your S8 Elite II on the floor beside or underneath your bed. Ensure that the area is free from dust and clear of bedding, clothes or any other objects that could block the air inlet.
  • Page 14: Start Treatment

    Fit your mask as described in the mask user instructions. WARNING A mask should not be used unless the S8 Elite II device is powered and operating properly. When ramping begins, the LCD will display the word "RAMPING", with the current pressure indicated as dashes.
  • Page 15: Using The Mask-Fitting Feature

    Using the Mask-Fitting Feature You can use the S8 Elite II mask-fitting feature to help you fit your mask properly. This feature delivers air pressure for a three-minute period, prior to starting treatment, during which you can check and adjust your mask fit to minimise leaks.
  • Page 16 Table 1: Definitions of Mask-Fit Star Rating Star rating Definition ***** Excellent ****- Very good ***-- Good **--- Adjust mask *---- Adjust mask ----- Adjust mask How to Use the S8 Elite II...
  • Page 17: Humidaire 3I

    HumidAire 3i. Reattach the connector plug firmly after you detach the humidifier. Storing the HumidAire 3 Store the HumidAire 3i in its mesh-top pouch in the S8 Elite II carry bag when not in use. How to Attach a Humidifier...
  • Page 18: Lcd Screen

    How to use the Keypad The control panel of the S8 Elite II includes an LCD screen and keypad for navigating through the menus and delivering treatment. LCD screen Up key Right key Left key Start/Stop key Down key LCD Screen The LCD screen displays the menus and treatment screens.
  • Page 19: How To Change The Settings

    You can change settings on the S8 Elite II by using the keypad and LCD. When the S8 Elite II is in standby mode you can display a series of screens (a menu) on the LCD screen in order to view and change the settings for a particular function.
  • Page 20: How To Use The Standard Menu

    How to Use the Standard Menu Figure 1 shows the standard menu. WELCOME >>>>>> RAMP: 10min menu EPR SETTING: 1 change exit exit USAGE: 1000/1068 exit MASK: ULTRA change exit SW: SX3960200 exit Figure 1: Standard menu screen You enter the standard menu from the standby (RAMP) screen, by pressing the Left (menu) key.
  • Page 21 Other viewable information You can also view the total number of hours of treatment (USED HRS); the number of sessions for which the S8 Elite II was used in a usage period (USAGE); and the current software version (SW). How to Use the Standard Menu...
  • Page 22: How To Use The Detailed Menu

    How to Use the Detailed Menu Figure 2 shows the detailed menu. WELCOME >>>>>> RAMP: 10min menu SETTINGS enter exit change exit MASK: ULTRA change exit TUBE LENGTH: 2m change exit change exit SMARTSTART: ON change exit LEAK ALERT: OFF change exit enter...
  • Page 23: Settings Menu

    Settings Menu Select Enter (Left key) on the Settings menu to access the options in this menu. How to Change the Expiratory Pressure Relief Setting Your clinician may have set up your device to deliver expiratory pressure relief (EPR). This can be used to help ease any discomfort you may experience when breathing out during treatment.
  • Page 24: Results Menu

    Viewing Usage Information You can view the total number of hours of treatment (USED HRS) and the number of sessions for which the S8 Elite II was used in a usage period (USAGE). Options Menu Select Enter (Left key) on the Options menu to access the options in this menu.
  • Page 25 Your clinician can set any of the following reminders on your LCD: Message Description Action INSERT CARD May appear if your Insert your Data Card (see Section H of the device is Data Card illustrations sheet), and follow any enabled. instructions that your clinician has given you.
  • Page 26: S8 Modules

    The blank module is a protective cover on your S8 Elite II. At times, you may wish to remove or attach the module, for example to use another module. To remove the blank module, pull it off the back of the S8 Elite II to show the data communications port (F-1).
  • Page 27 1 Insert the Data Card Switch on the S8 Elite II and wait until you see the standby (RAMP) • screen. Hold the Data Card with the arrow facing up, and insert it into the slot in • the Data Card module (H-1).
  • Page 28 Store the Data Card in its mailback envelope when not in use. • WARNING If your clinician has told you to use this Data Card to update the settings on your device and the “Settings Success” message does not appear, contact your clinician immediately.
  • Page 29: Cleaning And Maintenance

    UMIDIFIER If you are using a humidifier, remove it from the S8 Elite II and clean it according to the instructions in the humidifier user’s manual. Weekly Cleaning 1.
  • Page 30: Air Filter Cover

    Inspect the air filter every month to check if it is blocked by dirt or contains holes. With normal use of an S8 Elite II, the air filter needs to be replaced every six months (or more often if your device is in a dusty environment).
  • Page 31: Frequently Asked Questions

    Can I travel with the S8 Elite II? NTERNATIONAL USE Your S8 Elite II flow generator has an internal power supply that enables it to operate in other countries. It will operate on power supplies of 100–240V and 50/60Hz. No special adjustment is necessary, but you will require an approved power cord for the region in which you are using the device.
  • Page 32 Please consult the medical services department of your carrier if you intend to use your S8 Elite II on an aircraft. The S8 Elite II complies with US FCC Part 15, Class B requirements if no external data cables are used.
  • Page 33: Troubleshooting

    Troubleshooting If there is a problem, try the following suggestions. If the problem cannot be solved, contact your equipment supplier or ResMed. Do not attempt to open the device. Problem Possible Cause Solution No display. Power not connected. Ensure the appropriate power...
  • Page 34 Check tube!! front of the S8 Elite II. Key if done When you have checked the air tubing, press the Start/Stop key to restart the device. If this does not clear the...
  • Page 35 If this message appears again, contact your clinician. Display error Component failure. Return your S8 Elite II for message: servicing. Exxxx (where xxxx defines an error) The following The Data Card is not inserted...
  • Page 36 Problem Possible Cause Solution The following The Data Card is not inserted Ensure that the Data Card is message is displayed correctly. inserted with the arrow facing on the LCD after you up and pointing toward the try to copy data to a device.
  • Page 37: Air Outlet

    Dimensions (H x W x D): 112 mm x 164 mm x 145 mm Weight: 1.4 kg Power Supply Input range for S8 Elite II with HumidAire 3i: 100–240V, 50/60Hz; 110V, • 400Hz; 2.5A <140VA (110W) (maximum power consumption). Instantaneous peak power consumption <340VA.
  • Page 38: Accessories

    Noise Level AutoSet Spirit II—CPAP mode, 10 cm H O set pressure Measured total A-weighted sound pressure level 24 dBA (dB re 20 μPa) Uncertainty (dB re 20 μPa) 2 dBA Measured values are determined according to the noise test procedure given in ISO 17510-1.
  • Page 39 The crossed-bin symbol invites you to use these disposal systems. If you require information on collection and disposal of your ResMed device please contact your ResMed office, local distributor or go to www.resmed.com/environment. System Specifications...
  • Page 40 Guidance and Manufacturer’s Declaration — Electromagnetic Emissions and Immunity Guidance and manufacturer’s declaration—electromagnetic emissions The S8 series of devices is intended for use in the electromagnetic environment specified below. The customer or the user of the S8 device should assure that the device is used in such an environment.
  • Page 41: System

    Guidance and manufacturer’s declaration—electromagnetic immunity The S8 series of devices is intended for use in the electromagnetic environment specified below. The customer or the user of the S8 device should assure that the device is used in such an environment. Electromagnetic IEC60601-1-2 Compliance...
  • Page 42 Guidance and manufacturer’s declaration—electromagnetic immunity The S8 series of devices is intended for use in the electromagnetic environment specified below. The customer or the user of the S8 device should assure that the device is used in such an environment. Immunity IEC60601-1-2 Compliance...
  • Page 43 Recommended separation distances between portable and mobile RF communications equipment and the S8 series of devices The S8 series of devices is intended for use in an environment in which radiated RF disturbances are controlled. The customer or the user of the S8 device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the S8 device as recommended below, according to the maximum output power of the communications equipment.
  • Page 44: Limited Warranty

    ResMed shall not be responsible for any incidental or consequential damages claimed to have occurred as a result of the sale, installation or use of any ResMed product. Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
  • Page 45: Index

    Index accessories 6 frequently asked questions 25 air filter 5, 27 front cap 17 replacing 24 front cap (muffler) 6 air pressure 27 air tubing 5 cleaning 23 headgear position 27 connect to air outlet 7 HumidAire 3i 6 kinked 27 attaching 11 positioning 8 storage 11...