DIAGNOSTICS OF OPTICAL PICKUP
AND REPLACING TRAVERSE UNIT
Make failure diagnostics of the Optical Pickup as follows.
If the laser drive current (Iop) becomes more than 1.5 times of
the initial value, the Optical Pickup should be replaced.
The laser drive current initial value is checked by "Iop checked
Method" of next page.
In case of replacing the Pickup, change the whole part of the
Traverse Unit.
No mechanical adjustment is necessary after the replace-
ment.
Disc no read, unsteady playback, etc.
Laser drive current (Iop) check
HF wave form check
(Refer to WAVE FORMS)
Present value exceeds the ini-
tial value by 1.5 times
Traverse Unit replacing
Laser current (Iop) memorizing after replacement
レーザー駆動電流初期値 :
Laser drive current initial value:
FL Display (The display part of 13 digits)
DVD:
1
2
3
4
FL Display (The display part of 13 digits)
CD:
1
2
3
4
1
光ピックアップの故障診断とトラバース
ユニットの交換
次の順序で故障診断を行ってください。
レーザー駆動電流 Iop 値が初期値の 1.5 倍以上になっている
場合は光ピックアップ交換の目安となります。
レーザー駆動電流初期値は、次ページ "Iop 値の確認方法 " で
確認できます。
ピックアップ交換の場合は、トラバースユニット単位での交
換となります。メカの調整は不要です。
5
6
7
8
9
10
5
6
7
8
9
10
ディスクを読み込まない
スムーズに再生しない、等
レーザー駆動電流 Iop 値の確認
HF 波形の確認
(WAVE FORMS 参照)
トラバースユニット交換
交換後にレーザー電流値の記憶
12
11
12
13
11
12
13
現在値が初期値の
1.5 倍になっている
S-102