c. Configure the Video traffic Policer.
1.
Go to Network Settings > QoS > Policer Setup Setup
2.
Click Add New Policer.
3.
Check the Enable box.
4.
Enter the Policer Name box, e.g. "test".
5.
Select the Meter Type as "Simple Token Bucket".
6.
Enter the Committed Rate as "350".
7.
Enter the Committed Burst Size as "100".
8.
Select the Conforming Action as "Pass".
9.
Select the Non-Conforming Action as "Drop".
10. Select the Class in Available Class field and add to Selected Class.