Denon AVR-X3100W Service Manual page 62

Hide thumbs Also See for AVR-X3100W:
Table of Contents

Advertisement

3.7. Operation Info Mode
3.7.1. Actions
This mode displays the accumulated operating time, power on count and each protection count.
3.7.2. Starting up
Hold down buttons "ZONE2 SOURCE", "DIMMER" and "STATUS" at the same time and press the power button to turn on
the power.
Select the "4. OP INFO" using the button "TUNER PRESET CH+ / -", and press the button "STATUS" to commit the
selection.
3.7.3. Operations
Press the "STATUS" button after starting this device in Operation Info mode.
The following information is displayed in the following order.
(a) Accumulated operating time
FLD
O P
T i m e
(b) Power on count
FLD
P . O n
(c) DC / ASO Protection count
FLD
D C : / A S O :
(d) Thermal Protection count
FLD
T H M
(e) Thermal Protection count
FLD
T H M
(f)
CURRENT Protection count
FLD
C u r r e n t :
(Returns to normal display)
"STATUS"
T i m e
"STATUS"
"STATUS"
A :
/ B :
"STATUS"
E :
/ F :
"STATUS"
"STATUS"
H
↑Time display
↑Count display
62