Wireless Base Station - Viessmann VITODENS 200-W Technical Manual

Gas condensing boilers 17.0 to 150.0 kw as multi boiler system up to 900.0 kw
Table of Contents

Advertisement

Control units
(cont.)
– Operating condition
– Solar yield as graphic display
■ Settings:
– Set room temperatures for standard mode (day temperature) and
reduced mode (night temperature)
– Set DHW temperature
– Heating program, switching times for heating circuits, DHW heat-
ing and DHW circulation pump plus further settings via plain text
menu on the display
– Party and economy mode can be enabled via the menu
■ Integral room temperature sensor for room temperature hook-up
(only for one heating circuit with mixer)
Installation location:
■ Weather-compensated mode:
Installation anywhere in the building.
■ Room temperature hook-up:
The integral room temperature sensor captures the actual room
temperature and affects any necessary correction of the flow tem-
perature.
The captured room temperature is dependent on the installation
location:
– Main living room on an internal wall opposite radiators.
– Not on shelves, in recesses.
– Never immediately by a door or heat source (e.g. direct sunlight,
fireplace, TV set, etc.).
Note
Observe the "Wireless accessories" technical guide.
Standard delivery:
■ Vitotrol 300 RF
■ Wall mounting bracket
■ Power supply unit for installation into a plaster box
■ Two NiMH batteries for operating outside the wall mounting bracket
1 4
3
Vitotrol 300 RF

Wireless base station

Part no. Z011 413
KM BUS subscriber.
For communication between the Vitotronic control unit and the follow-
ing wireless components:
■ Vitotrol 200 RF wireless remote control
■ Vitotrol 300 RF wireless remote control
■ Wireless outside temperature sensor
For up to 3 wireless remote control units. Not in conjunction with a
hardwired remote control unit.
VITODENS 200-W
2 2
9 0
2 3
Wall mounting bracket
Specification
Power supply via power supply unit
230 V~/4 V
for installation into a plaster box
Power consumption
Radio frequency
Wireless protocol
Wireless range
Safety category
IP rating
Permissible ambient temperature
– During operation
– During storage and transport
Range of the room temperature
Connection:
■ 2-core lead, length up to 50 m (even when connecting several KM
BUS subscribers).
■ Never route this cable immediately next to 230/400 V cables.
2.4 W
868.3 MHz
EnOcean
See "Wireless accesso-
ries" technical guide
II
IP 30 to EN 60529
Ensure through assembly/
installation
0 to +40 °C
−25 to +60 °C
3 to 37 °C
VIESMANN
59
5