9.3
FLAME ADJUSTMENT
9.4
FLAME CHARACTERISTICS
It's important to periodically perform a visual check of the pilot and
burner fl ames. Compare them to the illustrations provided. If any fl ames
appear abnormal call a service person.
9.5
RESTRICTING VERTICAL VENTS
Vertical terminations may display a very active fl ame. As this
appearance is not desirable, the vent exit must be restricted
using restrictor plate, W500-0205. This reduces the velocity
of the exhaust gases, slowing down the fl ame pattern and
creating a more traditional appearance.
Remove the two screws on either side of the exhaust collar
inside the fi rebox. Install the plate as shown. Replace the
screws.
Turn clockwise to
increase fl ame height
ADJUSTMENT
FLAME
KNOB
FLAME MUST
ENVELOPE UPPER
3/8" TO 1/2" OF
THERMOCOUPLE &
THERMOPILE
3/8" - 1/2"
54.2
TOP OF THE FIREBOX
RESTRICTOR PLATE
W415-0779 / A / 04.27.10
37