7.2

INSTALLING THE BLOWER

INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must
be electrically connected and grounded in accordance with local codes.
In the absence of local codes, use the current CSA C22.1 Canadian
electrical code in Canada or the ANSI / NFPA 70 National Electrical Code
in the United States.
If the appliance was not previously equipped with a blower:
Route a grounded 2-wire, 60hz power cable to the receptacle /
junction box. At this point, it must be strain relieved and insulated.
The three slots on the blower mounting bracket allow ease of adjustment when
attaching the blower. For a quiet running blower, do not allow the assembly to
sit on the firebox base. Slide the vibration reducing pad (A) into the clip (C) and
up against the threaded stud (B) at the other end. The blower must be able to
be positioned entirely onto the pad.
To ease installation of the blower, remove the hinge screen and valve control door
(lower louvres) from the base of the appliance.
Tilt the blower onto its side. Slide it past the controls and into the clip (C).
Secure to the threaded stud using the lock washer and wing nut provided.
Ensure that the blower does not touch the appliance base or the firebox.
Attach the connectors from the black and white
wires to the thermal switch and secure the
thermal switch bracket to the bottom left of the unit
using the screws provided. Ensure that the
thermal switch touches the firebox wall.
Attach the connectors from the black and red
wires to the blower.
Attach and secure the variable speed switch
using the nut provided. Plug the harness cord
into the receptacle.The wire harness provided
in this kit is a universal harness. When installed,
ensure that any excess wire is contained,
preventing it from making contact with
moving or hot objects.
Because the blower is thermally activated,
when turned on, it will automatically start
approximately 10 minutes after lighting the appliance and will run for approximately 30-45 minutes after the
appliance has been turned off. Use of the fan increases the output of heat. Drywall dust will penetrate into the
blower bearings, causing irreparable damage. Care must be taken to prevent drywall dust from coming into
contact with the blower or its compartment. Any damage resulting from this condition is not covered by the
warranty policy.
W415-0779 / A / 04.27.10
THERMAL
SWITCH
B
A
THERMAL SWITCH
RECEPTACLE /
JUNCTION BOX
GROUND
SCREW
BLOWER
white
VARIABLE
SPEED
SWITCH
ELONGATED
SLOTS
C
VARIABLE
SPEED
KNOB
51.1