RFSUV34 Vent-Free Heater
FK24 Fan Kit
It is easier to install the fan before connecting the gas
line.
1. Open front access door panel by pulling forward on
handle.
2. Install the fan through the opening at the back of
the pedestal, with the outlet pointed up and the fan
mounting bracket facing the back of the fireplace. The
fan mounts over two studs which hold the fan just below
the firebox floor. Hold the fan in place with the two nuts
provided. (Fig. 14)
3. Locate the fan speed control/junction box on screw
studs provided on base of the fireplace. Tighten with
nuts.
4. Install thermal sensor element on screw studs located
to the right of the gas valve on the burner base.
5. Plug in grounded service cord to a convenient wall
receptacle.
Stud
Thermal Sensor
Location
Valve
HS114
Fig. 14 FK24 fan location.
HS114
FK24 fan
install
12/02
14

Accessories

Fan is
installed at
the back
of the
pedestal.
Fan Speed Control/
Juction Box
Remote Controls
Optional remote control units are available to control
different functions of the appliance.
Model
Function(s) Controlled
RC1
ON/OFF
RC2
ON/OFF and Temperature
IMTFK
Wall mounted thermostat control
Glass and Catalyst Filter
The RFSGDCFK glass and catalyst filter is available for
the RFSUV34 freestanding vent free heater.
10001769