Outdoor Fan Motor Operation; Airflow Direction - Panasonic CS-HZ9RKE Service Manual

Hide thumbs Also See for CS-HZ9RKE:
Table of Contents

Advertisement

ii. Auto Fan Speed
[Cooling, Dry]
According to room temperature and setting temperature, indoor fan speed is determined automatically.
The indoor fan will operate according to pattern below.
Fan
Speed
a
Higher
Medium
Lower
[Fan]
Indoor fan speed is fixed at predetermined speed.
[Heating]
According to indoor pipe temperature, automatic heating fan speed is determined as follows.
B. Feedback control
Immediately after the fan motor started, feedback control is performed once every second.
During fan motor on, if fan motor feedback ≥ 2550 rpm or < 50 rpm continue for 10 seconds, then fan motor error
counter increase, fan motor is then stop and restart. If the fan motor counter becomes 7 times, then H19 - fan
motor error is detected.
Operation stops and cannot on back.

13.3 Outdoor Fan Motor Operation

Outdoor fan motor is operated with 15 fan speed number of rotations. It starts when compressor starts operation and
it stops 30 seconds after compressor stops operation.
Compressor:
Outdoor Fan:

13.4 Airflow Direction

1. There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by
vertical vanes).
2. Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat
exchanger temperature and intake air temperature) and manual (angles of direction can be adjusted using
remote control).
b
c
d
RPM Increased
39
o
C
RPM Reduced
o
19
C
OFF
Indoor Pipe Temp.
ON
Fan Speed
ON
30 sec
[1 pattern : 10 s]
e
f
g
RPM Maintain
35
o
C
o
16
C
OFF
OFF
43
h
a
b
ON
ON

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents