INSTALLER/CONFIGURATION MENU
To enter the menu: Press the Menu touch key . Press and hold for 5 seconds the Installer Config touch key . This displays
menu item #1 in the table below . Press
or
to change a menu item .
Installer Note: To default the programming, clock and Configuration Menu to the Factory Default Settings, press the
and SYSTEM keys simultaneously . The thermostat display will go blank for a few seconds, and then all segments will display
momentarily . For heat pump systems, Configuration Menu item 1 must be set to match the heat pump system.
Menu
Non-
Reference
Program-
Program-
Number
mable
mable
1
1
1
2
2
2
3
3
3
4
4
NA
5
5
4
6
6
NA
7
7
5
8
8
6
9
9
7
10
10
8
11
11
9
12
12
10
13
13
11
14
14
12
15
15
13
16
16
14
17
17
15
18
18
16
19
19
17
20
20
18
21
21
19
22
22
20
23
23
21
24
24
22
25
25
23
26
26
24
27
27
25
4
to advance to the next menu item or
CONFIGURATION MENU
Displayed
Press
Press
(Factory
select from listed
Button
Default)
options
MS 2
HP 1, HP 2, SS 1
(ELE)
Days, (7) P
5-1-1 or 0
PS (4)
Cool-Off-
Cool-Off-Heat,
Heat-Auto
Off-Heat, Cool-Off
Cool-Off-Heat-
Cool-Off-Heat-Emer,
Emer-Auto
Off-Heat-Emer,
Cool-Off
E (On)
Cr, Heat (FA)
Cr, Cool (FA)
Cr/AU, Emer (FA)
CL (OFF)
dL (On)
dL (LO)
0
4, LO to 4, HI
°F
b (On)
dS (On)
AS, Heat (On)
AS, Cool (On)
CS, (OFF)
1-2-3-4-5-6
Cool Savings
HL, Heat (99)
LL, Cool (45)
L (total), P (partial),
OFF,
Temperature Limit
Keypad Lockout
(limited temperature
000
001-999
FS, Heat (On)
FS, Cool (On)
Remote (OFF)
In, Remote
Outdoor Remote
LS (On)
dF (5)
Cd (60)
Change Filter
(OFF)
200 Hours
25-1975
(in increments
of 25 hours)
to return to a previous menu item . Press
or
to
Comments
Selects Multi-Stage (MS 2, No Heat Pump), Heat Pump 1
(HP 1, 1 compressor), Heat Pump 2 (HP 2, 2 compressor
or 2 speed compressor), or Single Stage
GAS
GAS setting: furnace controls blower
ELE setting: thermostat controls blower
Programs per week . (0 = non-programmable)
2
Program periods per day
4 = Morning, Day, Evening, Night
2 = Day, Night
System switch configuration in non heat pump mode
System switch configuration, heat pump mode
OFF
Selects Energy Management Recovery, E (with programming option on)
SL
Selects Adjustable Anticipation, cycle rate, Heat
SL
Selects Adjustable Anticipation, cycle rate, Cool
SL
Selects Adjustable Anticipation, cycle rate auxiliary, (This item is
only to appear if HP 1 or HP 2 is selected above)
On
Selects Compressor Lockout
OFF
Selects Continuous Display backlight & intensity
HI
Selects Backlight Intensity
Selects Adjustable Ambient Temperature Display [range -4 (LO)
to +4 (HI)]
°C
Selects °F/°C Display (temperature units in Fahrenheit or Celsius) .
OFF
Selects audible Beeper On/Off
OFF
Selects Daylight Saving Time calculation
OFF
Selects Automatic Schedule for comfort temperature Programming,
heat mode
OFF
Selects Automatic Schedule for comfort temperature Programming,
cool mode
Selects Cool Saving Feature & amount
62-98
TEMPERATURE LIMIT, HEAT (max . heat set point)
46-82
TEMPERATURE LIMIT, COOL (min . cool set point)
Selects Keypad Lockout
range)
Selects Keypad Lockout Combination (active only if keypad Lockout
is selected) .
OFF
Fast second stage of heat (not available if SS1 is selected above)
OFF
Fast second stage of cool (not available if SS1 or HP1 is selected
above)
On
Remote temperature sensor, enable/disable
Remote temperature sensor (Indoor/Outdoor)
OFF
Local temp . Sensor enable/disable (only when Indoor Remote is
selected On) .
5-50
Selects Dual Fuel Feature & set point (in Fahrenheit) (applicable only
when HP1 or HP2 is selected)
0-99
Selects Compressor delay in seconds (only when dF is selected >5)
On
Selects Change filter feature
Change filter, duration hours
,