Installer Configuration Menu - White Rodgers 90 Series Installation And Operating Instructions Manual

90 series blue single stage touchscreen non-programmable thermostat with automatic heat/cool changeover option
Hide thumbs Also See for 90 Series:
Table of Contents

Advertisement

INSTALLER/CONFIGURATION MENU
To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Config touch key. This displays
menu item #1 in the table below. Press
or
to change a menu item.
Menu
Non-
Reference
Program- Program- Press
Number
mable
mable
1
1
1
2
2
2
3
3
NA
4
4
3
5
NA
5
6
6
4
7
7
5
8
8
6
9
9
7
10
8
10
11
9
11
12
12
10
13
13
11
14
14
12
15
13
15
16
16
14
17
17
15
18
16
18
19
17
19
20
20
18
21
19
21
22
22
20
to advance to the next menu item or
CONFIGURATION MENU
Displayed
Press
(Factory
to select from
Button
Default)
listed options
(ELE)
Days, (7) P
5-1-1 or 0
PS (4)
Cool-Off-
Cool-Off-Heat,
Heat-Auto
Off-Heat, Cool-Off
E (On)
Cr, Heat (FA)
Cr, Cool (FA)
CL (OFF)
dL (On)
dL (LO)
0
4, LO to 4, HI
°F
b (On)
dS (On)
AS, Heat (On)
AS, Cool (On)
CS, (OFF)
1-2-3-4-5-6
Cool Savings
HL, Heat (99)
LL, Cool (45)
OFF ,
L (total), P (partial),
Keypad Lockout
Temperature Limit
(limited temperature range)
000
Remote (OFF)
In, Remote
Outdoor Remote
LS (On)
Change Filter
(OFF)
200 Hours
25-1975 (in increments Change filter, duration hours.
of 25 hours)
to return to a previous menu item. Press
or
Comments
GAS
GAS setting: furnace controls blower.
ELE setting: thermostat controls blower.
Programs per week. (0 = non-programmable)
2
Program periods per day.
4 = Morning, Day, Evening, Night
2 = Day, Night
System switch configuration.
OFF
Selects Energy Management Recovery, E (with programming option on)
SL
Selects Adjustable Anticipation, cycle rate, Heat
SL
Selects Adjustable Anticipation, cycle rate, Cool
On
Selects Compressor Lockout.
OFF
Selects Continuous Display backlight & intensity.
HI
Selects Backlight Intensity.
Selects Adjustable Ambient Temperature Display [range -4 (LO) to
+4 (HI)].
°C
Selects °F/°C Display (temperature units in Fahrenheit or Celsius).
OFF
Selects audible Beeper On/Off.
OFF
Selects Daylight Saving Time calculation.
OFF
Selects Automatic Schedule for comfort temperature Programming,
heat mode.
OFF
Selects Automatic Schedule for comfort temperature Programming,
cool mode.
Selects Cool Saving Feature & amount.
62-98
TEMPERATURE LIMIT, HEAT (max. heat set point).
46-82
TEMPERATURE LIMIT, COOL (min. cool set point).
Selects Keypad Lockout.
001-999
Selects Keypad Lockout Combination (active only if keypad Lockout
is selected).
On
Remote temperature sensor, enable/disable.
Remote temperature sensor (Indoor/Outdoor).
OFF
Local temp. Sensor enable/disable (only when Indoor Remote is
selected On).
On
Selects Change filter feature
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

1f97-1277