Installer Configuration Menu - White Rodgers 1F86-0471 Installation And Operating Instructions Manual

Single stage or heat pump 80 series thermostat with automatic heat/cool changeover option
Table of Contents

Advertisement

INSTALLER/CONFIGURATION MENU
Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the
next menu item. Press
MENU
PRESS
REF.
HP
SS BUTTON (FACTORY DEFAULT) select from listed options
1
1
MENU
2
2
1
MENU
3
3
2
MENU Cool Saving CS (OFF)
4
4
3
MENU
5
4
MENU
6
5
MENU
7
5
MENU
8
6
6
MENU
9
7
7
MENU
10
8
8
MENU
11
9
9
MENU
12
10
10
MENU
13
11
11
MENU
14
12
12
RUN
1) Select Reversing Valve Output (Heat Pump switch S8
must be set at HP) – The O/B option is factory set at
"O" position. This will accommodate the majority of heat
pump applications, which require the changeover relay to
be energized in COOL. If the thermostat you are replac-
ing or the heat pump being installed with this thermostat
requires a "B" terminal, to energize the changeover relay
in HEAT, the O/B option should be set at "B" position.
2) Program Options: This control can be configured for 5/2
day or 5/1/1 day programming or non-programming mode.
The default setting is P2, indicating 5/2 day programming.
The programs per week can be toggled to P3 or P0 by
pressing the
or
non-programmable will eliminate the need for EMR, and
that step in the menu will be skipped.
3) Select Cool Savings™: With Cool Savings™ enabled,
the thermostat will make small adjustments to the setpoint
temperature during periods of high demand to reduce AC
4
or
to change a menu item.
INSTALLER/CONFIGURATION MENU
DISPLAYED
Press
On (Cool O)
P (2)
Cool Saving CS On
CS (3)
E (On)
CR Heat
(ME)
CR Cool
(FA)
CR Heat Pump
(FA)
CL (OFF)
Auto Heat
Cool Off
Heat Off with Fan icon,
Heat Off without Fan
Cool Off Heat
Heat Off with Fan icon,
Fan icon, Cool Off
L (On)
0 HI
1 HI, 2 HI, 3HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
F
Change Filter (OFF)
Change Filter 200 h
25-hour increment
keys. A selection of 0 Days for
or
to
Heat b On
Reversing Valve Output (Heat Pump switch S8
must be in the Heat Pump HP position)
P 3, P 0
6, 5, 4, 2, 1
Selects Cool Savings value 1 (low) to 6 (high)
E OFF
Selects Energy Management Recovery (EMR)
FA, SL
Adjustable Anticipation (Heat) (only when
heat pump switch is at the SS position)
SL
Adjustable Anticipation (Cool) (only when
heat pump switch is at the SS position)
SL
Adjustable Anticipation (Heat Pump) (only
when heat pump switch is at the HP position)
CL On
Heat Cool Off,
icon, Cool Off,
Auto Off
Heat Off without
L OFF
Adjustable Ambient Temperature Display
C
Selects Fahrenheit/Celcius Temperature Display
Change Filter On
25 h to 1975 h in
When on, selects time in 25 hour increments
system running time and save energy. When the cooling
system has been running for more than 20 minutes,
humidity in the home will be lower and a higher setpoint
temperature will feel comfortable. After 20 minutes of run
time, the thermostat will start increasing the setpoint
temperature in steps of less than one degree as the
system continues to run. These adjustments will eventu-
ally cause the system to satisfy the thermostat to turn the
system off and reduce the energy consumption. When
the Cool Savings™ feature is active and making adjust-
ments, the display will show "Save" next to the setpoint
temperature. The amount of the adjustments to the
setpoint temperature is dependent on the Cool Savings™
value that is set, 1 being the least adjustment and 6 being
the most adjustment. With this feature set to OFF , no
change will occur when the AC system is continuously
running during the periods of high demand. Periods of
high demand will normally occur during the late afternoon
and early evening on the hottest days of the summer.
COMMENTS
Selectable Programs Per Week
(For programmable thermostat only)
Select Cool Savings on or off
on or off
Compressor Lockout Time
System Mode Configuration
with Automatic Changeover
System Mode Configuration
without Automatic Changeover
Selects Display Light on or off
Selects Filter Change-out Indicator
Returns to Normal Operation