Maintenance; Annual Inspection; Filters; Burners - Goodman xMVM97 Series Installation Instructions Manual

Modulating gas furnace
Table of Contents

Advertisement

M
AINTENANCE
A
I
NNUAL
NSPECTION
The furnace should be inspected by a qualified installer, or service
agency at least once per year. This check should be performed at
the beginning of the heating season. This will ensure that all fur-
nace components are in proper working order and that the heating
system functions appropriately. Pay particular attention to the fol-
lowing items. Repair or service as necessary.
Flue pipe system. Check for blockage and/or leakage. Check
the outside termination and the connections at and internal
to the furnace.
Heat exchanger. Check for corrosion and/or buildup within the heat exchanger passageways.
Burners. Check for proper ignition, burner flame, and flame signal.
Drainage system. Check for blockage and/or leakage. Check hose connections at and internal to furnace.
Wiring. Check electrical connections for tightness and/or corrosion. Check wires for damage.

Filters.

Use a combustion analyzer to check CO
F
ILTERS
F
M
ILTER
AINTENANCE
Improper filter maintenance is the most common cause of inad-
equate heating or cooling performance. Filters should be cleaned
(permanent) or replaced (disposable) every two months or as re-
quired. When replacing a filter, it must be replaced with a filter of
the same type and size.
F
R
ILTER
EMOVAL
Depending on the installation, differing filter arrangements can be applied. Filters can be installed in either the central return register
or a side panel external filter rack (upflow only). A media air filter or electronic air cleaner can be used as an alternate filter. Follow
the filter sizes given in the Recommended Minimum Filter size table to ensure proper unit performance.
To remove filters from an external filter rack in an upright upflow installation, follow the directions provided with external filter rack
kit.
H
U
F
R
ORIZONTAL
NIT
ILTER
Filters in horizontal installations are located in the central return register or the ductwork near the furnace.
To remove:
1. Turn OFF electrical power to furnace.
2. Remove filter(s) from the central return register or ductwork.
3. Replace filter(s) by reversing the procedure for removal.
4. Turn ON electrical power to furnace.
M
A
F
E
EDIA
IR
ILTER OR
LECTRONIC
Follow the manufacturer's directions for service.
B
URNERS
Visually inspect the burner flames periodically during the heating season. Turn on the furnace at the thermostat and allow several
minutes for flames to stabilize, since any dislodged dust will alter the flames normal appearance. Flames should be stable, quiet, soft,
and blue (dust may cause orange tips but they must not be yellow). They should extend directly outward from the burners without
curling, floating, or lifting off. Flames must not impinge on the sides of the heat exchanger firing tubes.
level after 5 minutes of run time.
2
EMOVAL
A
C
R
IR
LEANER
EMOVAL
T
O AVOID ELECTRICAL SHOCK
DISCONNECT ELECTRICAL POWER BEFORE PERFORMING ANY
. I

MAINTENANCE

F YOU MUST HANDLE THE IGNITER
. T
HANDLE WITH CARE
OUCHING THE IGNITER ELEMENT
,
WITH BARE FINGERS
ROUGH HANDLING OR VIBRATION
COULD DAMAGE THE IGNITER RESULTING IN PREMATURE
. O
FAILURE
NLY A QUALIFIED SERVICER SHOULD EVER
.
HANDLE THE IGNITER
T
O ENSURE PROPER UNIT PERFORMANCE
GIVEN IN THE RECOMMENDED
S
S
PECIFICATION
HEET APPLICABLE TO YOUR MODEL
54
WARNING
,
,
INJURY OR DEATH
,
CAUTION
,
ADHERE TO THE FILTER SIZES
M
F
S
T
INIMUM
ILTER
IZE
ABLE OR
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xcvm97 series

Table of Contents