The bearings in the induced draft blower and circulator blower motors are permanently lubricated by the manufacturer. No further
lubrication is required. Check openings on motor housing for accumulation of dust which may cause overheating. Clean as
necessary.
C
T
D
ONDENSATE
RAP AND
RAIN
Annually inspect the drain tubes, drain trap, and field-supplied drain line for proper condensate drainage. Check drain system for
hose connection tightness, blockage, and leaks. Clean or repair as necessary.
F
S
(Q
LAME
ENSOR
UALIFIED
Under some conditions, the fuel or air supply can create a nearly invisible coating on the flame sensor. This coating acts as an
insulator causing a drop in the flame sense signal. If the flame sense signal drops too low the furnace will not sense flame and will lock
out. The flame sensor should be carefully cleaned by a qualified servicer using emery cloth or steel wool. Following cleaning, the
flame sense signal should be as indicated in the Specifications Sheet.
B
L
I
EFORE
EAVING AN

NSTALLATION

Cycle the furnace with the thermostat at least three times. Verify cooling and fan only operation.
Review the Owner's Manual with the homeowner and discuss proper furnace operation and maintenance.
Leave literature packet near furnace.
R
R
EPAIR AND
EPLACEMENT
When ordering any of the listed functional parts, be sure to provide the furnace model, manufacturing, and serial numbers
with the order.
Although only functional parts are shown in the parts list, all sheet metal parts, doors, etc. may be ordered by description.
Parts are available from your distributor.
Functional Parts List-
Gas Valve
Gas Manifold
Natural Gas Orifice
Propane Gas Orifice
Igniter

Flame Sensor

Rollout Limit Switch
Primary Limit Switch
Auxiliary Limit Switch
Pressure Switch
Induced Draft Blower
Door Switch
B

LOWERS

S
(Q
S
YSTEM
UALIFIED
ERVICER
S
O
)
ERVICER
NLY
P
ARTS
Blower Motor
Blower Wheel
Blower Mounting Bracket
Blower Cutoff
Blower Housing
Inductor
Heat Exchanger with
Recuperator Coil
Coil Front Cover
Integrated Control Module
Transformer
O
)
NLY