Standing Pilot Ignition System Wiring - Heat & Glo 8000TRLP-OAKIPI Owner's Manual

Hide thumbs Also See for 8000TRLP-OAKIPI:
Table of Contents

Advertisement

3V TRANSFORMER
ON/OFF
WALL
SWITCH
NEUTRAL
BLACK WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
ON THE HOT SIDE
Figure 10.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram
D. Standing Pilot Ignition System Wiring
• This standing pilot ignition system wiring does not
require a 110 VAC supply to operate.
• It is recommended that a 110 VAC junction box be
installed for use with a fan or remote control. (See Figure
10.3 for junction box wiring).
STANDING
PILOT
WHT
RED
Figure 10.3 Standing Pilot Ignition Wiring Diagram
Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI • 2057-900 Rev. K • 12/07
PLUG-IN
FLAME SPARKER/
SENSOR
IGNITION
MODULE
(3V)
LOW VOLTAGE
VALVE
SEE NOTE 1
REMOTE
CONTROL
HOT
GROUND
WHITE WIRE
CAN BE
PLUGGED
INTO ANY
OF #1- #5
LOCATIONS
ON THE
NEUTRAL SIDE
VALVE
IGNITION MODULE
3 VAC
BATTERY
PACK
RED
ON/OFF SWITCH
TRANSFORMER
3 VAC
PLUG IN
*Note: Appliance will not operate unless properly grounded.
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Shock hazard.
• Replace damaged wire with type 105º C rated
• Wire must have high temperature insulation.
ON
OFF
ON/OFF
SWITCH
INTERMITTENT
I
PILOT
IGNITOR
S
WHT
ORG
GROUND TO
FIREPLACE
CHASSIS
PIGGYBACK
VALVE
CAUTION
WARNING
wire.
REMOTE SWITCH
PIGTAIL
OPTIONAL WALL SWITCH,
THERMOSTAT OR REMOTE
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8000tr-oak8000tr-oak-ipi

Table of Contents