Optional Wall Switch Or Thermostat Installation - Travis Industries 864 HO GS Installation Manual

Hide thumbs Also See for 864 HO GS:
Table of Contents

Advertisement

Optional Wall Switch or Thermostat Installation

Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace. The switch
must be installed by a qualified installer.
This fireplace may be installed with an optional wall switch or thermostat. The thermostat (or on/off
switch) wire should be passed through the grommet on either side of the fireplace near the gas inlet (see
item "a" below). The thermostat (or on/off switch) wires will interrupt the burner circuit (see item "b"
below).
If you wish to bypass the switch, connect the thermostat (on/off switch) wires directly to the green and
white wires (see "c" below).
If you wish keep the switch (series) – re-align the wires as shown in item "d" below. NOTE: The
on/off switch must be in the "ON" position for the thermostat (or on/off switch) to operate.
a
Thermostat
Wire Grommet
Green
White
Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Note:
When using a GreenSmart™ remote, use the receiver for on/off operation.
© Travis Industries
Installation
COMFORT
CONTROL
c
Bypass
Thermostat or
On/Off Switch
(for qualified installers only)
POWER SUPPLY
Red
Black
Red
Red
Black
AA
BATTERY
TRAY
d
Series
White
Green
4100728
b
Burner Circuit Wires
Green
White
MAIN
BURNER
Thermostat or
On/Off Switch
100-01254_000