Specifications
CPU units
Item
Basic
Operation speed
High-level
Built-in RAM
Program capacity
With expansion
Conventional type
No expansion
H type
Number of I/O points
Conventional type
With expansion
H type
With remote I/O
Internal relay
Data register
Operation memory
File register
Link register
Optional memory
Comment memory
Clock/Calendar function

Power supply units

Item
Rated voltage
Current consumption
Input
Surge current
Rated frequency
Operating
Output
Voltage range
Alarm contact capacity
Alarm contact operation
Alarm contact type
Leakage current
Breakdown voltage
Insulation resistance
Guaranteed lifetime
Overcurrent protection function
Fuse
Terminal screw
Module size
Note: Allowable voltage fluctuation range after startup for the FP2-PSD2 is -35% to +30%. At startup, apply -15% to + 30% the rated voltage for 100ms or more.
16-point DC input type
Item
FP2-X16D2
Rated input voltage
12 - 24VDC
Rated input current
Approx. 8mA (at 24VDC)
Input impedance
Approx. 3kΩ
Min. ON voltage/Min. ON current
9.6V/4mA
18
18
Max. OFF voltage/Max. OFF current
2.5V/1mA
OFF → ON
0.2ms or less
Response
time
ON → OFF
0.2ms or less
FP2 CPU unit
FP2-C1
FP2-C1D
FP2-C1SL
0.35 µ s or more
0.93 µ s or more
16k steps
32k steps
Max. 768 points
Max. 512 points
Max. 1600 points
Max. 2048 points
Max. 2048 points
4048 points
6000 words
0 to 143,333 words
(w/expansion 0 to 30,717 words)
256 words
F-ROM/EP-ROM
Optional memory unit
Optional memory unit
FP2-PSA1
100V - 120VAC
0.4A or less (at 100VAC)
0.2A or less (at 200VAC)
40A or less (55°C)
85 to 132VAC
2.5A max.
1500VAC for 1 minute (between input and ground terminals)
100 MΩ 500VDC (between input and ground terminals)
1 modul
DC input unit
32-point DC input type
FP2-X32D2
24VDC
Approx. 4.3mA (at 24VDC)
Approx. 5.6kΩ
19.2V/4mA
5.0V/1.5mA
0.2ms or less
0.3ms or less
FP2SH CPU unit
FP2-C2
60k steps
Not available
F-ROM/EP-ROM
FP2-PSA2
200V - 240V
0.7A or less (at 100VAC) 0.4A or less (at 200VAC)
30A or less (25°C)
47Hz ~ 63Hz
170 to 264VAC
30VDC 1A
When the ALARM LED of CPU unit is lit
1c contact
Between input and ground terminals, 0.75mA or less
20,000 hours at 55°C
Built-in overcurrent protection
Built-in type
M3
1 modul
1)
64-point DC input type
DC input type/Transistor output (NPN) type DC input type/Transistor output (PNP) type
FP2-X64D2
24VDC
Approx. 4.3mA (at 24VDC)
Approx. 4.3mA (at 24VDC)
Approx. 5.6kΩ
19.2V/4mA
09/2007
5.0V/1.5mA
0.2ms or less
0.3ms or less
FP2-C2P
FP2-C3P
0.03µs or more
0.06µs or more
120k steps
Not available
Max. 768 points
Max. 512 points
Max. 1600 points
Max. 2048 points
Max. 8192 points
14,192 points
10,240 words
32,765 words x 3 banks
8448 words
Small PC card (F-ROM/S-RAM)
Available
Available
FP2-PSA3
FP2-PSD2
100V - 240VAC
2.5A or less
10A or less
20.4 to 31.2VDC note)
85 to 264VAC
5A max.
2 module
I/O mixed unit (input side)
2)
FP2-XY64D2T
FP2-XY64D2P
24VDC
24VDC
Approx. 4.3mA (at 24VDC)
Approx. 5.6kΩ
Approx. 5.6kΩ
19.2V/4mA
19.2V/4mA
5.0V/1.5mA
5.0V/1.5mA
0.2ms or less
0.2ms or less
0.3ms or less
0.3ms or less
24VDC
2 module
3)

Advertisement