ETERNUS LT40 S2 tape library
4.2.7.2
Tape library error codes
If an error occurs during operation of the library, the library stops the current operation and
displays an error code on the LCD screen.
i
Example error code
EVENT -6
A5 F1
where:
Sequence number -6 indicates the position in sequence list, 0 being the most recent
●
Log shows a load error (code A5 = fan error, sub code F1 = caused by the fan at the
●
back connector plate).
The event log with the library also includes a date stamp for each event. Press the ENTER
key to display the associated timestamp in the following format:
ddd:hh:mm:ss:HH
dabei sind:
ddd: days
hh: hours
mm: minutes
ss: seconds
HH: 1/100 seconds
60
If an error message is issued, please notify Customer Support.
Periphery