Working With The Tape Library; Modes Of The Tape Library - Fujitsu SE700 Operating Manual

Hide thumbs Also See for SE700:
Table of Contents

Advertisement

ETERNUS LT40 S2 tape library

4.2.6 Working with the tape library

This section contains hardware-related information on working with the tape library when it
is used as a BS2000 device.
i
4.2.6.1

Modes of the tape library

The tape library is released for BS2000 operation in two modes (library modes): Random
Mode and Sequential Mode. "Autoload" and "Loop" modes can also be activated in
Sequential Mode. You can switch explicitly between Random and Sequential Mode, see
page
51.
Random Mode
Random Mode is the default operation mode and also the normal operation mode when
being used by BS2000. In Random Mode the application software controls when which
cartridge is mounted or ejected.
When a manual action is initiated by the OCP (or RMU), e.g. the export of a cartridge (i.e.
a cartridge is moved using the OCP menu Commands > Move Media, the tape library uses
Sequential Mode for the duration of this action and then switches back to Random Mode.
During this interruption of the current operation mode, the device displays "Busy Rand Action
Move" in the operator control panel. Messages to this effect are displayed on the BS2000
console. Messages also report when Randos Mode is disabled or enabled.
Sequential Mode
From the BS2000 viewpoint Sequential Mode corresponds to automatic or manual mode
with continuation tapes - all tapes are automatically used one after the other.
Sequential Mode has the additional options Autoload and Loop.
When Autoload is enabled and the drive is empty, the tape is loaded in the slot with the
lowest number after the tape library has been rebooted or powered-on.
When Loop is enabled, following the last tape operation continues again with the first
tape, otherwise the tape library will stop and wait for the user to intervene.
50
Cartridges without a label which are contained in the cartridge magazine are not
displayed by BS2000. You are therefore urgently recommended only to use
cartridges with a label.