S
TOVE
P
14
AGE
H
EARTH
S
D
TOVE
IRECT
C
ONNECTION
NOTE:
Direct
connections
require
installation of
an airtight
block-off plate
or damper
adapter (see
the section
"Block-off
Plate
Installation"
on page 18).
H
EARTH
S
TOVE
H
ORIZONTAL
C
ONNECTION
NOTE:
This type of
installation
requires a wall
radiation
shield
(thimble).
Either close
off and seal
the damper,
install a block-
off plate or
install a
damper
adapter (see
the section
"Block-off
Plate
Installation"
on page 18).
I
NSTALLATION
NOTE: This installation may be used
with a masonry or zero clearance
(metal) fireplace. The requirements in
the section "Masonry Fireplace
Requirements" or "Zero Clearance
(metal) Fireplace Requirements" must
be fulfilled prior to installation.
Combustible Mantle
Floor Protection
(See the section
"Floor Protection
Requirements" for
more details)
NOTE: This installation
may be used with a
masonry fireplace only.
The requirements in the
section "Masonry
Fireplace Requirements"
must be fulfilled prior to
installation.
Chimney
connector
sections
Combustible Mantle
Floor Protection
(See the section
"Floor Protection
Requirements" for
more details)
(C
.)
ONT
Min. 18"
Block-off plate or
damper adapter
Min. 18"
clearance
to ceiling
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
Flue Liner
Stainless steel
chimney connector
must Extend 1' past
the block-off plate
or to the flue liner
Airtight
Insulated
Clean-Out
Remove
damper
or wire it
open
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
Flue Liner
Follow the chimney
manufacturer's
instructions and
clearances for wall
penetrations. A wall
radiation shield
(thimble) is required.
Airtight
Insulated
Clean-Out
Either close off and
seal the damper,
install a block-off
plate, or install a
damper adapter.

Advertisement