8. Hook the unit to the mounting bracket and let the unit hang from the
mounting bracket.
9. Loosen 2 screws to remove the wiring compartment cover.
10. Run the electrical power supply cable and connect to the wiring
compartment via the knock-out at back side of the unit.
11. Make the correct electrical connections to the G80 and after making
the connections, arrange the pigtail leads of the unit and power supply
wires in the wiring compartment.
12. Replace the wiring compartment cover and lock in place with 2
screws.
13. Secure the unit to the bracket with screws.
14. Replace the housing and secure with screws.

OPERATION

The Select switch on the heater is for function selection only. Use the circuit
breaker as your power switch. The circuit breaker should be installed by a
certified electrician and be located in line of sight of the heater location or
should be capable of being locked in the open position. Follow the operating
instructions to reduce the risk of fire, electric shock, injury or death.
1.
Switch on the circuit breaker to turn on the heater.
2.
When the Select switch on the heater is at the FAN ONLY position, only
the fan is on.