Download Print this page

Configuring The Recorder - Interlogix TruVision NVR 10 Quick Start Manual

Hide thumbs Also See for TruVision NVR 10:

Advertisement

IR remote control
The IR remote control buttons are similar to
those on the front panel. Place the two AAA
batteries in the remote control.
To connect the remote control to the
recorder:
1. Press
Menu
on the front panel or right-click
the mouse and select Menu. The main
menu screen appears.
2. Select
Display Mode Settings
3. Check the recorder's device address value.
The default value is 255. The device
address is valid for all IR controls.
4. On the remote control press the
button.
5. Enter the device address value. It must be
the same as that on the recorder.
6. Press
OK
on the remote control.
USB mouse
The USB mouse provided with the recorder
operates all the functions of the recorder,
unlike the front panel, which has limited
functionality. The mouse lets you navigate and
make changes to settings in the user
interface.
Connect the mouse to the recorder by
plugging the mouse USB connector into the
USB port on the back or front panel. The
mouse is immediately operational and the
pointer should appear.
Web browser control
The recorder's Web browser lets you view,
record, and play back videos as well as
manage all aspects of the recorder from any
PC with Internet access. The browser's easy-
to-use controls give you quick access to all
recorder functions.
To access the unit, open a web browser and
enter the IP address assigned to the recorder
as a web address. In the logon screen, enter
the default user ID and password:
User ID: admin
Password: 1234
4
The default values for recorder network
settings are:
> Monitor.
Note: The following ports need to be
forwarded in the router in order to connect
properly: Server port and RTSP port.
Device
Figure 4: Web browser interface
Live view mode
Live mode is the normal operating mode of the
unit where you watch live pictures from the
cameras.
Regularly used functions in live view can be
quickly accessed by clicking the left-button of
the mouse when its cursor is on the camera
image. The shortcut pop-up toolbar appears.
See Figure 3 on page 2 for a description of
the functions available.

Configuring the recorder

The recorder has an icon-driven menu
structure that allows you to configure the unit's
parameters. Each command icon displays a
screen that lets you edit a group of settings.
Most menus are available only to system
administrators.
Refer to the recorder user manual for detailed
information on configuring the unit.
DHCP: Disabled by default.
IP address - 192.168.1.82
Subnet mask - 255.255.255.0
Gateway address - 192.168.1.1
Server Port: 8000
HTTP Port: 80
RTSP port: 554