Maintenance; General; Cleaning - Montigo P42DF Installation & Maintenance Manual

P series residential fireplace
Hide thumbs Also See for P42DF:
Table of Contents

Advertisement

P42DF* Indoor Gas Fireplace

Maintenance

General

Have the fireplace and installation inspected yearly. The inspection must
include, but is not limited to, the following:
A visual check of the entire vent system and termination.
An inspection of the explosion relief flappers and the door
gaskets to ensure a proper seal.
An inspection of the burner, vent run, and primary air openings.
An inspection of the gas valve, gas components, and pilot flame.
For your convenience a 1/8" manifold pressure tap is supplied
on the gas valve for a test gauge connection
Inspection of all equipment; fans, thermostats, etc.
For Natural Gas this appliance requires a minimum inlet pressure
of 5.5" W.C. and a manifold pressure of 3.5" W.C.
For Propane Gas this appliance requires a minimum inlet pressure
of 11" W.C. and a manifold pressure of 10" W.C.
Always keep the fireplace area clear and free of combustible
materials, as well as gasoline and other flammable vapours
and liquids.
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.
Inspection of glass doors and screen for damage and proper
installation.

Cleaning

When the fireplace is first activated, there may be some smoke and a
visible film may be left on the glass. This is a normal condition, and is
the result of burning of protective coatings on new metal.
Glass must be cleaned periodically to remove any film (which
is a normal by-product of combustion) which may be visible.
Film can easily be removed by removing the door, as shown on
Page 20. Handle the door carefully, and clean it with nonabrasive
glass cleaners. One of the most effective products is Kel Kem.
Silicone seals on inner door during initial firing will "off gas",
leaving a visual deposit of a white substance on combustion
chamber walls. This can easily be removed from the chamber
walls using normal household products.
Use a vacuum cleaner or whisk broom to keep the control
compartment, burner, and firebox free from dust and lint.
NOTICE
Do not use ammonia based or abrasive cleaners on the glass, they will permanently
etch the surface. Use an approved gas fireplace glass cleaner such as Kel-Kem or
White off.
Page 28
Maintenance
Pilot Burner Adjustment.
1. Locate Pilot Adjustment Screw. (See figure 27)
2. Adjust pilot screw to provide properly sized flame as shown.
3. After installing or servicing, leak test with a soap solution with main
burner on. Coat pipe and tubing joints, gasket etc. with soap solution.
Bubbles indicate leaks. Tighten any areas where the bubbles appear
until the bubbling stops completely.
Figure 27. Pilot Adjustment on the SIT Proflame 2 gas valve.
Manifold Pressure
Test Connection
Inlet Pressure
Test Connection
Pilot Adjustment Screw
XG0195 -150204.2