Dimmer Curves; Curve Settings; Control Panel Lock; Passcode - Chauvet ColorAdo 1-Quad IP User Manual

Hide thumbs Also See for ColorAdo 1-Quad IP:
Table of Contents

Advertisement

Operation

Dimmer Curves

Curve Settings

Control Panel
Lock

Passcode

Settings Lock

-12-
This setting determines how fast the output of the COLORado™ 1-Quad IP changes when
you modify the values of the red, green, blue, white, and dimmer faders. This setting
provides four different options to simulate the dimming curve of an incandescent lighting
product.
1. Go to the SET main level.
2. Select DIM.
3. Select a dimmer curve (OFF, DIM1, DIM2, DIM3, or DIM4).
OFF:
The output is proportional (linear) to the dimmer and RGBW channel values.
DIM1–4:
The output follows the dimmer and RGBW channel values based on the
corresponding dimmer curve, DIM1 being the fastest and DIM4 the slowest.
This setting allows you to select the dimmer curve shape using the red, green, blue, white,
and dimmer faders.
1. Go to the SET main level.
2. Select CURV.
3. Select a dimmer curve (OFF, CV1, CV2, or CV3).
OFF:
The output is proportional (linear) to the dimmer and RGBW channel values.
DIM1–4:
The output follows the dimmer and RGBW channel values based on the
corresponding dimmer curve, CV1 being the fastest and CV3 the slowest.
For optimum control of the 16-bit dimming channels in the TR16 and FULL
personalities, be sure that both dimming curves in SET > DIMX and SET > CURV are
set to OFF.
This setting enables you to activate or disable the control panel lock, which keeps non-
authorized personnel from changing the product's settings.
1. Go to the SET main level.
2. Select KEY.
3. Select ON or OFF.
When the control panel lock is active, the product will prompt you to enter the passcode
after 30 seconds of control panel inactivity or after turning on the product.
After being prompted to enter the passcode:
·
Press <UP>, <DOWN>, <UP>, <DOWN>, <ENTER>.
This setting enables you to activate or disable the settings lock, which keeps non-
authorized personnel from making any changes to the programming levels under the SET
main level..
1. Go to the SET main level.
2. Select SLCK.
3. Select ON or OFF.
When the settings lock is activated, in order to access the SET programming levels, the
product will prompt you to enter the passcode. Enter the passcode as described in
Passcode.
COLORado™ 1-Quad IP User Manual Rev. 5