Connecting Condensate Drain Tube To Heater - Rinnai RHFE-750ETR Installation Manual

Power flued flamefire space heater co-axial flue system
Hide thumbs Also See for RHFE-750ETR:
Table of Contents

Advertisement

CONNECTING CONDENSATE DRAIN TUBE TO HEATER

Condensate Drain Kit
A condensate kit is provided with the heater and will need to be
installed for "Internal Wall" flue installations or other vertical flue
installations that will require draining of the condensate products
back into the heater.
Failure to install the condensate kit correctly may
cause damage to the heater and flue system.
CAUTION
Connection Of Condensate Hose To Condensate Trap
Condensate
Drain Hose
Condensate
Tube
At least 10mm
penetration of
1
barb is required
1. Insert the barbed end of the condensate tube into the condensate drain hose, ensure that the barb penetrates
the hose by at least 10mm.
2. Locate the condensate tube insertion point, which is a rubber grommet found at the rear of the heater to the
right of the combustion air hose connection.
Insert the condensate tube through the rubber grommet until you reach the 90° bend.
3.
Uncoil the condensate drain hose and secure it to the rear of the heater using the upper screw of the
combustion fan cover and the wire tie provided.
Rubber Drain
Outlet
Condensate
Hose
4
Before connecting the condensate drain hose to the condensate trap ensure that there are no kinks
in the condensate drain hose. Also ensure that the path of the condensate drain hose is kept it
CAUTION
away from hot surfaces.
4. Connect the free end of the condensate drain hose to the rubber drain outlet of the condensate trap by pushing
the hose inside the rubber connection to a minimum of 20mm but not greater than 30mm.
Inserting the condensate drain hose into the rubber drain outlet of the condensate trap more than
30mm can cause blocking of the drain-way.
CAUTION
Installation Of Condensate Tray
5.
Place the condensate tray into the heater "short end first" making sure that the tray is centred under the end
of the condensate tube that was installed in step 2.
Rinnai Australia
.
Combustion Air Hose Connection
Rubber Grommet
Insertion Point For
Condensate Tube
2
FRONT
Barb (Top)
Condensate
Tube
90° Bend
Condensate Tube Inserted
Up To the 90° Bend
REAR
Short end
towards REAR
of heater
Long end
towards FRONT
of heater
5
21
Short End
Condensate
Drain Hose
Wire Tie
3
Rubber Grommet
Condensate Tube
For Condensate Tube
Condensate
Tray
ASP Flue Installation Manual
Long End
Condensate
Tray
Wire Tie

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents