Connecting Condensate Drain Tube To Heater - Rinnai RHFE-308FTR Installation Manual

Energysaver co-axial flue system
Hide thumbs Also See for RHFE-308FTR:
Table of Contents

Advertisement

INSTALLATION METHODS

CONNECTING CONDENSATE DRAIN TUBE TO HEATER

1.
Condensate trap "ESCONDK".
2.
Carefully mark and drill a 16 diameter mm hole through both the heat shield panel and
appliance back panel. DO NOT allow the drill to penetrate further than 10 mm past
the back panel as damage to the heat exchanger or internal components will occur.
To insert the condensate drain hose in the appliance drill through both the
raised heat shield and the heater back panel.
CAUTION
A 16 mm diameter hole is required for the correct clearance with the
condensate drain hose supplied.
DO NOT allow the drill to penetrate further than 10mm past the back panel
as damage to the internal components such as the heat exchanger will
occur.
UNDER NO CIRCUMSTANCES MUST THE APPLIANCE BE OPERATED WITH A
DAMAGED HEAT EXCHANGER
WARNING
The condensate drain tube pipe and the pipe clip are available as a spare part from Rinnai, part
number 90180944.
NOTE
2
RHFE-556FTR/FDT
Back panel
Heat Shield
65
80
RHFE-308FTR
Back panel
Heat Shield
120
All vertical measurements are from floor level.
* The horizontal measurements are taken from the edge of the raised back panel.
3.
Feed approximately 60mm of the free end of the drain tube through the drilled holes created in step 2. above.
Ensure that any condensation can drain into the condensation tray of the heater.
DO NOT allow any portion of the drain tube to come into contact with any part of the heat
exchanger.
CAUTION
DO NOT kink, crimp or sharply bend any portion of the condensate drain tube.
4.
Secure the drain tube to the rear of the appliance with a pipe clip, (clip not included).
Rinnai
RHFE-559FT/FDT/FT2/FDT2
RHFE-309FT/FT2
Back panel
Heat Shield
90
120
Back panel
Heat Shield
115
80
RHFE-1004FTR/FDT
RHFE-1005FT/FDT/FT2/FDT2
*
Drill the lower heat shield ONLY!
75
Dim 'B'
30
1
Rubber
Drain
Outlet
Drain Tube*
*Drain tube & clamp
spare part No. 90180944)
RHFE-557FTR
RHFE-561FT/FT2
Back panel
Heat Shield
115
120
*Dim 'A'
Dim 'B'
510mm 135mm
500mm 100mm
Back panel
Heat
*
Shields
*Dim 'A'
ES_FIM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents