Miscellaneous Settings; Before Requesting Service - Sanyo SPW-C256VH Technical Data & Service Manual

4-way air discharge semi-concealed wall-mounted ceiling-mounted concealed-duct
Table of Contents

Advertisement

8-14. Miscellaneous Settings

A variety of changes can be made to settings, depending on the indoor unit being used.
Wind direction (fl ap) indicator, operation mode indicator, time display (24 hour, AM/PM), heat max temp
• For information about the fl ap function, refer to the users' manual of the unit being used.
• (These settings are saved in nonvolatile memory in the remote control, so even when its batteries are changed,
the settings do not have to be made again.)
• First check the display of the remote control when the unit is stopped and then make any desired settings.
How to Operate
• While holding down the buttons below, every time
• Whatever is being displayed when you release
Setting Item
Remote control fl ap display
setting for when
Remote control operation
mode display setting when
is pressed
Clock display setting
Max possible temperature
setting in the Heat mode

8-15. Before Requesting Service

Before requesting service, please check the followings.
Problem
The unit doesn't work
even when
is pressed
on the remote control.
The air conditioner
starts and stops on its
own.
" " is displayed on the
remote control when the
unit is stopped.
Although the unit is for air conditioning only, either Auto or Heat is indicated
in the display.
After putting the batteries in the remote control, even when it is operated,
the display does not change.
8
The timer cannot be set.
If the problem persists even after you check the foregoing items, stop the unit, disconnect the power to the indoor
unit and contact the dealer where the product was purchased with the model number and problem you are having.
As it is dangerous, under no circumstances should you undertake repairs yourself.
Further, when the receiver's
*1 RCS-SS80BG.WL is an operation panel
*2 RCS-SS80BG.WL is a display
Operation Button
Press
is pressed
while pressing
Press
while pressing
Press
while pressing
Press
while pressing
The power to the indoor unit is not ON.
Is the Normal/Stop All switch in the Stop All position?
(See Page 8-4)
Are the remote control's batteries dead?
Is there a mismatch between the display lamp and
cooling/heating or is it set to something other than
Auto? (The operating lamp stays lit, while the timer
lamp and the standby lamp blink alternately.)
Do the addresses match one another?
Has the timer been set to repeat?
An error has occurred in the non-volatile memory.
*2
lamps are blinking; please contact your retailer with that information.
is pressed the remote control's display changes.
is set.
Setting Content
Models with movable fl aps
Swing only models
Models w/o lamps
Heat Pump (with Auto)
Heat Pump (without Auto)
Dedicated air conditioner
24 Hour
AM/PM
Maximum heating
temperature
range is 26°C – 30°C
Cause
8-10
Remote Control Display
None
Solution
Make sure the power to the indoor unit is ON.
Switch it to the Normal position and cancel
operation.
Change the batteries.
Change the operating mode.
Check the addresses of the receiver
remote control. (See Page 8-7)
Check the timer settings.(See Page 8-6)
Please contact your sales outlet.
Make settings to the remote control's operation
mode display. (See the above table.)
Press the Reset button on the remote control.
(See Page 8-5)
Make the settings when the remote control is
in Operation Display. (See Page 8-6)
and the
*1

Hide quick links: