2) Maximum and Minimum Frequency Control

The compressor's inverter frequency is controlled in accordance with the model and operation mode.
The maximum and minimum frequencies for each model are shown in the table below.
* There are cases in which frequency is limited with other control functions depending on operational conditions,
so operations are not always carried out in accordance with the maximum frequencies listed below.
<Single-phase>
Type
Maximum Frequency (Hz)
Minimum Frequency (Hz)
<3-phase>
Type
Maximum Frequency (Hz)
Minimum Frequency (Hz)
* There are cases in which the frequency is set at 24.0Hz~28.0Hz to protect the compressor in accordance with
outdoor air temperature and indoor loads.

3) Current Release Control

The inverter frequency is controlled so that the current value for the inverter compressor is less than the fi gure
listed in the table below only in the cooling mode in order to prevent abnormal increases in the inverter circuit
located within the outdoor unit's electrical box.
(1) Current release control with primary current : The limited values are modifi ed in accordance with outdoor
<Single-phase>
Type
256
Cooling
17.0
Is(A)
Heating
17.5
NOTE
The limited values are lowered when the outdoor air temperature is higher than 40
and higher than 14

4) Cooling High-Load Prevention Control

This control is performed to limit the inverter frequency in order to restrict abnormal increases in pressure and
high-load operations in the cooling mode. In accordance with the temperature of the outdoor heat exchanger
temperature sensors (C1, C2), such controls are performed as halting the operations of the indoor unit,
decreasing the inverter frequency and restricting its increase, etc. If the temperature max (C1, C2) exceeds
64 , operations of the indoor unit are halted and then restarted 3 minutes later. If this start/stop activity is
repeated 10 times consecutively, alarm "P20" (cooling high-load error) occurs.
max. (C2, C1)
a
b
c
d
e
256
Cooling
98.0
Heating
103.2
Cooling
15.0*
Heating
15.0*
256
Cooling
63.0
Heating
69.0
Cooling
28.2
Heating
28.2
air temperature.
366
486
21.0
28.5
22.0
28.5
in the heating mode.
Outdoor unit operations halted
Frequency decreased
Frequency increases prevented
Frequency increased slower than normal
Normal operations (no control)
366
486
87.0
78.0
95.2
80.0
18.0*
20.0*
18.0*
20.0*
366
486
606
87.0
78.0
80.0
95.2
80.0
85.0
28.2
20.0*
20.0*
28.2
20.0*
20.0*
<3-phase>
Type
256
Cooling
4.8
Is(A)
Heating
4.8
<Single-phase>
Type
a
b
c
d
e
<3-phase>
Type
a
b
c
d
e
4-3
366
486
606
6.2
12.0
13.5
6.2
13.0
15.0
in the cooling mode
256
366
486
64
64
61
60
59
55
58
57
53
57
56
51
53
53
49
256
366
486
606
64
64
61
61
64
64
57
57
55
55
55
55
55
55
53
53
55
55
51
51
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents