BHT_RF_SetParamStr
Description
Write character string to the wireless communications parameter.
Syntax
DWORD BHT_RF_SetParamStr (
DWORD
dwParam
TCHAR*
pwchData
DWORD
dwLen
)
Parameters
dwParam
[in] Parameter number
dwParam
P_STR_WEPKEY1
P_STR_PRESHAREDKEY Pre Shared Key
pwchData
[in] Heading address of the storage buffer for data specified
dwLen
[in] Length of data specified
Return value
Error code
ERROR_SUCCESS
ERROR_INVALID_PARAMETER Parameter error
ERROR_NOT_SUPPORTED
,
,
Specification
WEP Key 1
Successful completion
Not supported.
Meaning
127