The floor drain system requires a siphon break that may be
purchased separately. See "Tools and Parts."
The siphon break must be a minimum of 28" (710 mm) from the
bottom of the washer. Additional hoses might be needed.
Back view
ElectricalRequirements
Electrical
Shock
Hazard
Plug into a grounded
3 prong outlet.
Do not remove
ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow
these
instructions
can result
in
death,
fire, or electrical
shock.
[]
A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended.
It is recommended
that a separate circuit
serving only this washer be provided.
[]
This washer is equipped with a power supply cord having
a 3 prong grounding plug.
[]
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type
outlet,
grounded in accordance with local codes and ordinances.
If a mating outlet is not available, it is the personal
responsibility
and obligation of the customer to have the
properly grounded outlet installed by a qualified electrician.
[]
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrician determine that the
ground path is adequate.
[]
Do not ground to a gas pipe.
[]
Check with a qualified electrician if you are not sure the
washer is properly grounded.
[]
Do not have a fuse in the neutral or ground circuit.
GROUNDING
iNSTRUCTiONS
For a grounded, cord=connected washer:
This washer must be grounded, in the event of a malfunction
or breakdown, grounding will reduce the risk of electrical
shock by providing a path of least resistance for electric
current. This washer is equipped with a cord having an
equipment=grounding
conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are
in doubt as to whether the appliance is properly grounded.
Do not modify the plug provided with the appliance - if it will
not fit the outlet, have a proper outlet installed by a qualified
electrician.
For a permanently
connected washer:
This washer must be connected to a grounded metal,
permanent wiring system, or an equipment grounding
conductor must be run with the circuit conductors and
connected to the equipment=grounding
terminal or lead
on the appliance.
iNSTALLATiON i NSTRUCTiONS
Remove Transport System
Excessive
Weight Hazard
Use two or more people to move and install washer.
Failure to do so can result in back or other injury.
iMPORTANT: Position the washer so that the rear of the washer
is within approximately
3 ft. (900 mm) of its final location.
There are 4 shipping bolts in the rear panel of the washer that
support the suspension system during transportation.
These bolts
also retain the power cord inside the washer until the bolts are
removed.
1. Keep the washer in the upright position while removing the
shipping bolts.
Shipping
bolt
Shipping bolt with plastic spacer