Important Message; Specifications; General Safety Information - Regency C34 Owners & Installation Manual

Classic direct vent freestanding gas stove
Table of Contents

Advertisement

IMPORTANT MESSAGE

SAVE THESE
INSTRUCTIONS
The CLASSIC Direct Vent Freestanding Gas Stove
must be installed in accordance with these instruc-
tions. Carefully read all the instructions in this
manual first. Consult the building authority having
jurisdiction to determine the need for a permit prior
to starting the installation.
- WARNING -
Failure to follow the instructions could
cause a malfunction of the heater
which could result in death, serious
bodily injury, and/or property damage.
Failure to follow these instructions
may also void your fire insurance and/
or warranty.
Note: These instructions take precedence over
Simpson Dura-Vent instructions

SPECIFICATIONS

Fuels: C34-NG10 is approved for use with natural
gas. C34-LP10 is approved for use with
liquefied petroleum gases (propane).
Electrical: 120V. A.C. system.
Optional circulation fan: 125/75 CFM.
Log Sets: Ceramic fibre, 4 per set.
Vent System: Coaxial (6 5/8" outer/ 4" inner liner)
rigid flue and termination cap.
SHOULD OVERHEATING OCCUR, OR
THE GAS SUPPLY FAIL TO SHUT OFF,
SHUT OFF THE MANUAL GAS VALVE
TO THE APPLIANCE BEFORE SHUT-
TING OFF THE ELECTRICAL SUPPLY.
- WARNING -
Risk of fire or electric shock. Only
qualified service personnel shall be
used to install and provide mainte-
nance of this appliance.
1. Provide adequate clearances for servicing,
proper operation and around the air openings
into the combustion chamber.
2. The appliance may be installed on a flat, solid,
continuous surface (e.g. wood, metal, concrete).
This may be the floor, or it can be raised up on
a platform to enhance its visual impact. If the
appliance is going to be installed on carpeting,
see clearances to combustibles in "Clearances
to Combustibles" section.
The CLASSIC Direct Vent Freestanding Gas
Stove can be installed in a wide variety of ways
and will fit nearly any room layout. It may be
installed in a recessed position, framed out into
the room, or across a corner. This appliance is
Listed for Alcove installations, maintain minimum
Alcove clearances as follows, minimum ceiling
height of 65-11/16", minimum width of 48" and
a maximum depth of 36".
3. The CLASSIC Direct Vent Freestanding Gas
Stove is approved for alcove installations, which
meet the clearances listed in "Clearances to
Combustibles" section. This unit can be installed
in a bedroom, when installed with a millivolt ther-
mostat. This unit is approved for manufactured
home installations, see "Venting Arrangements"
section for the required vent arrangements. If
installed into a manufactured or mobile home
the unit must be bolted down to the floor.
4. We recommend that you plan your installation on
paper using exact measurements for clearances
and floor protection before actually installing this
appliance. Have a qualified building inspector
review your plans before installation.
Regency
installation
GENERAL SAFETY
INFORMATION
1. The appliance installation must conform with
local codes or, in the absence of local codes,
with the current Canadian or National Electrical
Codes, CAN1-B149 or ANSI Z223.1 Installation
Codes.
2. The appliance when installed, must be electri-
cally grounded in accordance with local codes,
or in the absence of local codes with the current
National Electrical Code, ANSI/NFPA 70 or CSA
C22.1 Canadian Electrical Code.
3. The appliance should be inspected for shipping
damage before use and serviced annually by
a professional service person. More frequent
cleaning may be required due to excessive
lint from carpeting, bedding material, etc. It
is imperative that control compartments, and
circulating air passageways of the appliance
be kept clean.
4. See general construction and assembly in-
structions. The appliance and vent should be
enclosed when installed in or passing through
a living area.
5. This appliance must be connected to the speci-
fied vent and termination cap to the outside of
the building envelope.
6. Never vent to another room or inside a build-
ing. Make sure that the vent is fitted as per the
instructions starting in "Venting Introduction"
section.
7. Inspect the venting system annually for blockage
and any signs of deterioration.
8. Venting terminals shall not be recessed into a
wall or siding.
9. Any safety glass removed for servicing must
be replaced prior to operating the appliance.
10 To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the fireplace.
Emissions from burning
contain chemicals known to the State of Cali-
fornia to cause cancer, birth defects or other
reproductive harm.
CLASSIC C34-10 Direct Vent Freestanding Gas Stove
®
|
9
wood or gas could
|
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents