DUPLEX TESTS

Duplex Quick Test

This test verifies if the Duplex Option Top Margin is set correctly. This test prints a duplexed version of the Quick
Test Page that can be used to adjust the Top Margin for the back of the duplexed page. You can run one
duplexed page (Single) or continue printing duplexed pages (Continuous) until Stop (
You must use either Letter or A4 paper.
1.
From the Diagnostics menu, navigate to:
DUPLEX TESTS > Duplex Quick Test
2.
Select Single or Continuous.
The single test cannot be canceled.
The printer attempts to print the Quick Test Page from the default paper source. If the default paper
source supports only envelopes, then the page is printed from Tray 1.
Check the Quick Test Page for the correct offset between the placement of the first scan line on the
front and back side of a duplexed sheet.
If adjustment is necessary, the Top Margin in the Registration menu must be adjusted first. The
Duplex Top Margin Offset may be adjusted next.
A positive offset moves the text down the page and widens the top margin, while a negative offset
moves the text up the page and narrows the top margin.
3.
Press Stop (

Duplex Top Margin Offset

Modification of this setting controls the offset between the placement of the first scan line on the front and back
side of a duplex sheet.
Changing the value by 1 unit moves the margin by 1/100 inches. A positive value moves the text down the page
and widens the top margin. A negative value moves the text up the page and narrows the top margin.
Touch Back to return to the DUPLEX TESTS menu.

INPUT TRAY TESTS

Feed Test

This test feeds blank pages through the paper path.
Note: This test can run using any of the paper or envelope sizes supported by the printer. The pages are placed
in the default output bin; however, the Feed Test menu lets you select the input source.
1.
From the Diagnostics menu, navigate to:
INPUT TRAY TESTS > Feed Test
2.
Select the input source. All installed sources appear.
3.
Select either Single (feeds one sheet of media from the selected source) or Continuous (continues to
feed from the selected source until Stop (
4.
Press Stop (
3-18
Service Manual
X
) to cancel the test.
X
) to exit the test.
X
) is pressed).
X
) is pressed.