INSTALLER: Please leave these instructions with the
owner.
OWNER: Please retain these instructions for future
reference.
WARNING: Any change to this heater or its con-
trols can be dangerous.
IMPORTANT: READ THESE INSTRUCTIONS CARE-
FULLY BEFORE INSTALLING.
WARNING: If the area in which the heater may be
operated is smaller than that defined as an uncon-
fined space or if the building is of unusually tight
construction, provide adequate combustion and
ventilation air by one of the methods described in
the National Fuel Gas code, ANSI Z223.1/NFPA 54,
Section 5.3, (or applicable local codes).
NOTES
Due to high temperatures, the appliance should be lo-
cated out of traffic and away from furniture and draperies.
The appliance area must be kept clear and free from com-
bustible materials, gasoline and other flammable vapors and
liquids.
Children and adults should be alerted to the hazard of
high surface temperatures and should stay away to avoid
burns or clothing ignition.
Installation and repair must be done by a qualified ser-
vice person or gas appliance installer.
The appliance must be inspected before use and at least
annually by a professional service person. More frequent
cleaning may be required due to excessive lint from carpet-
ing, bedding material, dust and pet hair, etc. It is important
that the control compartment, burners and circulating air
passageways of the appliance be kept clean.
DO NOT place clothing or other flammable material on or
near the appliance.
This appliance must only be used with pressures at the inlet
as shown in Table 1, Page 13.
The installation must conform with local codes or, in the
absence of local codes, with the NATIONAL FUEL GAS CODE,
ANSI Z223.1/NFPA 54, latest edition.
Any safety screen or guard removed for servicing an ap-
pliance must be replaced prior to operating the heater.
The appliance and its appliance main gas valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 PSIG (3.5 kpa).
The appliance must be isolated from the gas supply piping
system by closing its equipment shut-off valve during any test-
ing of the gas supply piping system at test pressures equal to or
less than 1/2 PSIG.
DO NOT use this heater in recreational vehicles, bedrooms or
bathrooms.
If this is the ONLY gas appliance, we recommend a
minimum 200 pound cylinder with a fill gauge. Use of a 100
pound cylinder is not recommended. Other household gas
appliances may require the tank size to be larger. Do not
4

Important Information

operate the vent-free heater if the fuel level in the propane
tank is below 1/4 full. Use only with two-stage regulator.
water. Immediately call a qualified technician to inspect the ap-
pliance and replace any part of the control system and any gas
control which has been under water.
closed at the time of appliance installation.
heaters are permitted. If unvented heaters are not per-
mitted, the fireplace chimney damper must be fixed at a
minimum dimension of 34 sq. inches. This must be ac-
complished by a clamp or screw on the chimney damper
to stop at the minimum vent area. The fireplace must also
have a minimum vent opening of 34 sq. ins., (Fig. 1)
factured "mobile" home where not prohibited by state or local
codes.
*After-market: Completion of sale, not for purpose of re-sale
from the manufacturer.
MUST BE CLOSED AND SEALED.
are in the same room with the appliance.
than 10,000 btu per hour shall not be installed in a bedroom
or bathroom.
tenance instructions in this manual.
open.
logs are on.
masonry or UL 127 factory-built fireplace in which an unvented
room heater is installed.
This appliance may be installed in an aftermarket, perma-
nently located, manufactured (mobile) home, where not
prohibited by local codes.
This appliance is only for use with the type of gas indi-
cated on the rating plate. This appliance is not convertible
for use with other gases.
DO NOT use this heater if any part of it has been under
Any outside air ducts in the fireplace shall be permanently
Check local, state or city codes to determine if unvented
This appliance may be installed in an after-market* manu-
OUTSIDE AIR DAMPER OR ASH DUMP (IF PRESENT)
Young children should be carefully supervised when they
An unvented room heater having an input rating of more
Keep the burner and control compartment clean. See main-
The appliance must be operated with glass doors fully
DO NOT operate ceiling fan in room or area with logs when
Solid fuels (i.e. wood, paper, trash) shall not be burned in a
WARNING: This appliance is for installation only in
a solid-fuel burning masonry or UL 127 factory-built
fireplace or in a listed ventless firebox enclosure. It
has been designed certified for these installations.
Exception: DO NOT install this appliance in a fac-
tory-built fireplace that includes instructions stating
it has not been tested or should not be used with
unvented gas logs.
WARNING: Do not allow fans to blow directly into the
fireplace. Avoid any drafts that alter burner flame pat-
terns.