Models with "N" after the model number use natural gas; models with "P" after the model number use propane (LP) gas.
This appliance operates as an unvented room heat-
er certified under ANSI Z21.11.2b-2004 when fitted
to a solid fuel burning masonry or factory built fire-
place with the flue damper closed. It also operates
as a decorative appliance under ANSI Z21.60b-2001.
CSA 2.26b-2001, when fitted to a solid fuel burning
masonry or factory built fireplace with the flue
damper open. When used as a decorative appli-
ance, the use of a thermostat is not allowed. State
or local codes may only allow operation of this ap-
pliance in a vented configuration. Check your state
or local codes.
If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instruc-
tions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventila-
tion air must be provided. Refer to Section Provi-
sions For Adequate Combustion and Ventilation
Air - Page 6.
Installation and Operating Instructions for
Gas Log Heaters
Models: UVHK23MP, UVHK29MN,
UVHK31MP, UVHK36MN
WARNING
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Charred Oak Logs
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
Split Bark Logs
20008056 1/07 Rev. 2

Advertisement

Table of Contents
loading

Summary of Contents for Majestic fireplaces UVHK23MP

  • Page 1 Installation and Operating Instructions for Gas Log Heaters Models: UVHK23MP, UVHK29MN, Models with “N” after the model number use natural gas; models with “P” after the model number use propane (LP) gas. This appliance operates as an unvented room heat- er certified under ANSI Z21.11.2b-2004 when fitted...
  • Page 2: Table Of Contents

    Important Information ... 3 Important Safeguards ... 4 Installation Requirements ... 5 High Elevations ... 5 Pressure Test Points ... 5 Odor During Operation ... 5 Provisions For Adequate Combustion Air ... 7 Installation Unpacking ... 9 Fireplace Preparation ... 9 Location ...
  • Page 3: Important Information

    • The appliance must be operated with glass doors fully open. • DO NOT operate ceiling fan in room or area with logs when logs are on. • Solid fuels (i.e. wood, paper, trash) shall not be burned in a masonry or UL 127 factory-built fireplace in which an unvented...
  • Page 4: Important Safeguards

    WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusu- ally tight construction, provide adequate com- bustion and ventilation air by one of the methods described in the National Fuel Gas code, ANSI Z223.1/NFPA 54, Section 5.3, (or applicable local codes).
  • Page 5: Installation Requirements

    18” UVHK31MP Propane 28” 18” UVHK29MN Natural 23” 16” UVHK23MP Propane 23” 16” A. Front width C. Depth Fig. 1 Minimum fireplace dimensions. High Elevations Input ratings are shown in BTU per hour and are certified without deration from elevations up to 4,500 feet (1,370m) above sea level.
  • Page 6 SLS24 and CVLS24 ONLY ★ WARNING: Refer to the above table to ensure that your log set is certified to be used in the CFM Corporation Vent-Free firebox you have purchased. BR/BC and SHR models are designed as wood/solid fuel fireplaces. These wood-burning models must be installed as a wood-burning unit including chimney and termination cap before the installation of the vent-free logs.
  • Page 7: Provisions For Adequate Combustion Air

    Provisions for Adequate Combustion and Ventilation Air WARNING: This heater shall not be installed in a confined space or unusually tight construc- tion unless provisions are provided for adequate combustion and ventilation air. Today’s homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes.
  • Page 8 T104 Fig. 1 Minimum flue diameter and flue damper positions. WARNING: Air openings that provide fresh air from an adjoining unconfined space shall not be blocked or obstructed in any way. Installation of unit should allow a minimum of 2” clearance from any part of the heater to any of the ventilation openings.
  • Page 9: Installation

    flames and possibly cause sooting. Such drafts may be caused by a ceiling fan near the fireplace, a hot air furnace register or an open door. When burning the logs, carefully observe the effect of possible drafts on the flames and take appropriate...
  • Page 10 42" 16" Fig. 4A Minimum clearance to wall and ceiling. 10" 8" T105 Heat Resistant Material Minimum 6" clearance to walls & ceiling 10/27/03 djt Universal Min. Canopy Fireplace Opening Fig. 4C Mantel clearance with Optional Universal Canopy, UC-2 (black) or UC-2PB (polished brass). T107 Mantel clearance with canopy...
  • Page 11: Gas Connection

    Gas Connection Check Gas Type. Use only the gas type indicated on the heater’s rating plate. If the gas type indicated on the plate is not your type of gas supply, DO NOT INSTALL. Contact your dealer for the proper model. WARNING DANGER OF PROPERTY DAMAGE, BODILY INJURY OR DEATH.
  • Page 12: Gas Line Pipe Sizing

    NOTE: To determine the size of the branch gas line from the main gas line to the fireplace, enter the tables below (for iron pipe or copper tubing) using the distance from the gas meter or second stage regulator to the furthest appliance on the gas system.
  • Page 13: Lighting Instructions

    WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B.
  • Page 14: Flame Check

    Flame Check A periodic visual check of the flames should be made. The pilot flame should always be present when the appliance is in opera- tion. (Fig. 10) In normal operation (at full rate for approximately 15 minutes) the following flame appearance should be observed: Fig.
  • Page 15: Positioning Logs

    Positioning Logs The logs must be positioned ONLY as illustrated in Figures 12, 13 and 14 • Position the front log so that the large notch in the underside of the right end of the log fits securely and rests on the sheet metal control cover as shown in Figure 15.
  • Page 16 Fig. 13 Charred oak logset positions. WARNING: Failure to position the parts in accordance with this diagram or failure to use only parts specifically ap- proved with this heater, may result in property damage or personal injury. Do not alter the logs! Fig.
  • Page 17 Fig. 15 Position log so notch fits securely and rests on valve cover. Front Log Fig. 16 Front end of frontlog should touch grate bar. T101 secure front log 10/15/03 djt 20008056 Control Cover Valve Cover T100 T100 log notch Fig.
  • Page 18: Servicing

    Hardware Bag Assy Volcanic Rock Assy Tube, Flexible Gas Inlet CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Servicing cool before beginning any service operation.
  • Page 19: Warranty

    4. These warranties are limited to repair, replacement or fur- nishing a replacement for sale, as specified in Paragraphs A and B, for a part found to CFM Corporation satisfaction, after examination, to be defective in materials or workman- ship under normal conditions, use and service.
  • Page 20 CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.com...

This manual is also suitable for:

Uvhk29mnUvhk31mpUvhk36mn

Table of Contents