1.2

Overall View

A/23 MFFI - A/27 MFFI
Fig. 1.1
4
Supplied By www.heating spares.co Tel. 0161 620 6677
8 - Regulate the gas pressure, ignition pressure, partial flame, maximum flame.
9 - Check proper operation of the heating safety system:
- maximum safety temperature;
- maximum safety pressure.
10 - Check the proper operation of the gas safety system:
- gas or flame safety device;
- gas valve safety device.
11 - Check that the electrical connections have been made in compliance with the
instructions shown in the installation instructions.
12 - Check the efficiency of the hot water supply (flow and temperature).
13 - Check general operation of the appliance.
14 - Check the exhaust system for the combustion products.
Legend:
1.
Flue Connector
2.
Combustion Chamber Hood
3.
Main Heat Exchanger
4.
Combustion Chamber Insulation Panel
5.
Burner
6.
Expansion Vessel
7.
Overheat Thermostat
8.
Spark Generator
9.
Diverter Valve
10. Main Circuit Temperature Probe
11. Main Circuit Flow Switch
12. Diverter Valve Microswitch
13. Filter Seat
14. Drain Valve
15. Secondary Heat Exchanger
16. Safety Valve (3 bar)
17. Circulation Pump with Automatic Air Release Valve
18. Gas Valve
19. Detection Electrodes
20. Ignition Electrodes
21. Fan
22. Venturi
23. Air Pressure Switch